Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Lorentz Force Detuning K factor(Hz/(MV/m)^2) measured in-situ

NameDescription

SRF Example

(CM 2 Cavity 1)

 
Gun/Buncher Example 
RAT:GMAXDuring acceptance testing, maximum gradient. [MV/m]ACCL:L1B:0210:AT:GMAXN/A
RAT:AMAXDuring acceptance testing, maximum amplitude. [MV]ACCL:L1B:0210:AT:AMAXN/A
RAT:GUSEDuring acceptance testing, usable gradient. [MV/m]ACCL:L1B:0210:AT:GUSEN/A
RAT:AUSEDuring acceptance testing, usable amplitude. [MV]ACCL:L1B:0210:AT:AUSEN/A
RAT:FEON_GACTDuring acceptance testing, gradient at which field emission begins. [MV/m]ACCL:L1B:0210:AT:FEON_GACTN/A
RAT:FEON_AACTDuring acceptance testing, amplitude at which field emission begins. [MV]ACCL:L1B:0210:AT:FEON_AACTN/A
RAT:LIMITDuring acceptance testing, cavity limiting factor. 0 = Undefined, 1 = Quench, 2 = FE, 3 = SSA trip, 4 = Admin, 5 = RF power, 6 = OtherACCL:L1B:0210:AT:LIMITN/A
RAT:Q0During acceptance testing, cavity Q0 measured at 16 MV/mACCL:L1B:0210:AT:Q0N/A
RAT:QPROBEDuring acceptance testing, cavity probe Q external, coldACCL:L1B:0210:AT:QPROBEN/A
RAT:QHOM_CPLRDuring acceptance testing, Higher Order Mode coupler Q external, coldACCL:L1B:0210:AT:QHOM_CPLRN/A
RAT:QHOM_PICKUPDuring acceptance testing, Higher Order Mode pickup Q external, coldACCL:L1B:0210:AT:QHOM_PICKUPN/A


(from Chris Adolfsen. Garth wonders should this be a calibration attribute rather than physics interface?) Slow tuner start-up position prior to rf turn on - with the piezo voltages zeroed, the cavity would be tuned close to 1.3 GHz after the operating  gradient is established - thus the initial detuning with rf off relative to 1.3 GHz is K*(operating gradient)^2



(from Chris Adolfsen. Garth wonders should this be a calibration attribute rather than physics interface?) Slow tuner park position - this is the position the tuner would be set if one wants to detune the cavity so it does not interact with the beam.Q0Q0 measurement from partner labs, delivered with the cryomoduleQextQext measured in-situ (last measurement – used to calibrate cavity probe signal based on discharge power)LFD



Calibration of the slow tuner (Hz/step) measured in-situ



Calibration of the piezo tuners (Hz/volt) measured in-situ

Per Cryomodule
RSNCryomodule serial numberACCL:L1B:0200:SNN/A

 Signal calibration.

For SRF cavities, the PVs below are provided for CAV, FWD, REV, DRV signals. The SRF PV name examples below use CAV.

 Measured values
R/W  <SIG>:CAL_ADC_10DBMADC counts at 10 dBm. EPICS software uses this to calculate RF power at full scale.ACCL:L1B:0210:CAV:CAL_ADC_10DBM
R/W  <SIG>:CAL_LOSS_CABLEMeasured cable losses used in signal calibration. Positive value in dB.ACCL:L1B:0210:CAV:CAL_LOSS_CABLE
R/W  <SIG>:CAL_LOSS_CPLRMeasured coupler loss used in signal calibration. Positive value in dB.ACCL:L1B:0210:CAV:CAL_LOSS_CPLR
R/W <SIG>:CAL_LOSS_ATTENFixed attenuator used in signal calibration. Positive value in dB.ACCL:L1B:0210:CAV:CAL_LOSS_ATTEN
R/W  <SIG>:CAL_LOSS_OTHERUnattributed measured loss used in signal calibration. Positive value in dB.ACCL:L1B:0210:CAV:CAL_LOSS_OTHER
 EPICS-calculated values 
R <SIG>:CAL_REF_PWRRF power at ADC full scale. [dBm] ACCL:L1B:0210:CAV:CAL_REF_PWR
 <SIG>:CAL_LOSS_TOTALTotal (of cable, coupler, atten, other) loss used in signal calibration. Positive value in dB. ACCL:L1B:0210:CAV:CAL_LOSS_TOTAL 
 <SIG>:SCALEFinal calibration scale factor to convert raw ADC counts to amplitude. This also include the beam-based fudge factor ACCL:L1B:0210:CAV:SCALE
For SRF, the signal calibration for Cavity Probe (CAV) can be calculated 2 ways: (1) using the above system losses, power at ADC full scale, and cavity probe Q or (2) calculated from the reverse signal decay. Experts can choose which method they would like to use per cavity
 R/WCAVSCALE_SEL Select between calibration methods: 0 = Qprobe, 1 = RevCalACCL:L1B:0210:CAVSCALE_SEL 
 R/WQPROBE  Cavity probe Q. Used in Qprobe calibration method.ACCL:L1B:0210:QPROBE


Other attributes for operations -

...

Tentative

NameDescription
VChassis power supply voltage
TChassis board temperature
DCSSA enable/disable internal DC power

SSA RF enable, how to distinguish from global RF enable?

PzVout

Output voltage to the piezo tuning motor

PzHzExpected tuning change from PzVout


...