Page History
...
pixel size 100 x 225 microns in area in both directions.
Metrology map fro Chris Kenney
Comments on orientation of epix10ka2m parts from Matt
Code Block | ||||
---|---|---|---|---|
| ||||
Weaver, Matt Tue 10/9, 3:07 PMO'Grady, Paul Christopher;Dubrovin, Mikhail;Damiani, Daniel S. Also, here's some description of the nominal geometry. Pay close attention to the last part that describes the positioning of ASICs within an "element". I think this might be different than before. -Matt // // Hard code the array's geometry for now // // (Epix10ka2m) // | // Quad 3 | Quad 0 Quad 1 is rotated 90d clockwise // -------+-------- Quad 2 is rotated 180d clockwise // Quad 2 | Quad 1 Quad 3 is rotated 270d clockwise // | // // (Quad 0) // | // Elem 0 | Elem 1 // -------+-------- No rotations // Elem 2 | Elem 3 // | // // (Elem 0) // | // ASIC 0 | ASIC 3 // -------+-------- No rotations // ASIC 1 | ASIC 2 // | |
Code Block | ||
---|---|---|
| ||
Weaver, Matt 2018-11-18, 6:14 PMDubrovin, Mikhail;O'Grady, Paul Christopher Here's the geometry I'm now using (below). Note that pixel(0,0) for each of the elements below is in the lower right hand corner. We'll know the quadrant layout for sure when we get the radioactive source exposure on Monday. // (Epix10ka2m) // | // Quad 3 | Quad 0 Quad 1 is rotated 90d clockwise // -------+-------- Quad 2 is rotated 180d clockwise // Quad 2 | Quad 1 Quad 3 is rotated 270d clockwise // | // // (Quad 0) // | // Elem 0 | Elem 1 // -------+-------- No rotations // Elem 2 | Elem 3 // | // // (Elem 0) // | // ASIC 2 | ASIC 1 // -------+-------- No rotations // ASIC 3 | ASIC 0 |
Preliminary geometry