Page History
...
Code Block | ||
---|---|---|
| ||
Kenney, Christopher J. 2018-11-12, 2:26 PM
Guide tube is 7mm outer diameter
We added polyimide tape that was 150 microns thick before application
to the tube.
But a decent estimate would be the mechanical edge-to-edge orthogonal
separation between sensor edges 7.3 mm.
We need to add about 1 mm for the guard rings on each sensor
So the orthogonal gap between active pixels on opposing quads across
the beam guide tube should be 8.3 mm
====
Kenney, Christopher J. 2018-11-12, 4:41 PM Blaj, Gabriel;Dubrovin, Mikhail;Kwiatkowski, Maciej
Very rough estimate of the gaps
There are 3 types of gaps
All are active pixel to active pixel
sensor to sensor ~ 1.6 mm
CB to CB ~ 6.4 mm
sensor to CB ~ 3.9 mm
====
CB = Carrier Board edges
Full camera image below
====
so 384 columns parallel to the balcony (the widest dead gaps)
and 352 orthogonal to the balcony (vertical direction) |
epix10ka2m assembly
epix10ka2m-insensitive-gaps.pdf
...
Overview
Content Tools