Code Block | ||
---|---|---|
| ||
Kenney, Christopher J. 2018-11-12, 2:26 PM Guide tube is 7mm outer diameter We added polyimide tape that was 150 microns thick before application to the tube. But a decent estimate would be the mechanical edge-to-edge orthogonal separation between sensor edges 7.3 mm. We need to add about 1 mm for the guard rings on each sensor So the orthogonal gap between active pixels on opposing quads across the beam guide tube should be 8.3 mm ==== Kenney, Christopher J. 2018-11-12, 4:41 PM Blaj, Gabriel;Dubrovin, Mikhail;Kwiatkowski, Maciej Very rough estimate of the gaps There are 3 types of gaps All are active pixel to active pixel sensor to sensor ~ 1.6 mm CB to CB ~ 6.4 mm sensor to CB ~ 3.9 mm ==== CB = Carrier Board edges Full camera image below |
epix10ka2m assembly
epix10ka2m-insensitive-gaps.pdf
epix10ka sensor central region between 4 ASICs
The internal gap between four ASICs in sensor,
pixel size 100 x 225 microns in area in both directions.
...