 (from Chris Adolfsen. Garth wonders should this be a calibration attribute rather than physics interface?) Slow tuner start-up position prior to rf turn on - with the piezo voltages zeroed, the cavity would be tuned close to 1.3 GHz after the operating  gradient is established - thus the initial detuning with rf off relative to 1.3 GHz is K*(operating gradient)^2
 (from Chris Adolfsen. Garth wonders should this be a calibration attribute rather than physics interface?) Slow tuner park position - this is the position the tuner would be set if one wants to detune the cavity so it does not interact with the beam.
Q0Q0 measurement from partner labs, delivered with the cryomodule
QextQext measured in-situ (last measurement – used to calibrate cavity probe signal based on discharge power)
LFDLorentz Force Detuning K factor(Hz/(MV/m)^2) measured in-situ
 Calibration of the slow tuner (Hz/step) measured in-situ
 Calibration of the piezo tuners (Hz/volt) measured in-situ
 Signal calibration. The PVs below will be provided for FWD, REV, DRV signals.
 Measured values
 <SIG>:CAL_ADC_10DBMADC counts at 10 dBm. EPICS software uses this to calculate RF power at full scale.
 <SIG>:CAL_LOSS_CABLEMeasured cable losses for forward measurement used in signal calibration. Positive value in dB.
 <SIG>:CAL_LOSS_CPLRMeasured coupler loss for forward measurement used in signal calibration. Positive value in dB.
 <SIG>:CAL_LOSS_ATTENFixed attenuator for forward measurement used in signal calibration. Positive value in dB.
 <SIG>:CAL_LOSS_OTHERUnattributed measured loss for forward measurement used loss used in signal calibration. Positive value in dB. <SIG>:CAL_LOSS_TOTALTotal loss for forward measurement used in signal calibration. Positive value in dB.
 EPICS-calculated values 
 <SIG>:CAL_REF_PWRRF power at ADC full scale for forward measurement. In dBm. Analogous PVs exist for reverse and drive (aka loopback) signals.
 <SIG>:CAL_LOSS_TOTALTotal loss for forward measurement (of cable, coupler, atten, other) loss used in signal calibration. Positive value in dB.
 <SIG>:SCALECalibration scale factor to convert forward raw ADC counts to amplitude in sqrt(Watts). Calculated internally by RF software, based on system losses and ADC power at full scale.
Signal calibration for Cavity Probe  (CAV)
 CAV:CAL_SCALECalibration scale factor to convert cavity probe raw ADC counts to amplitude in MV. Calculated by LLRF calibration sequence. See CAV:SCALE for more info.
 CAV:SCALECalibration scale factor to convert cavity probe raw ADC counts to amplitude in MV. Is equal to product of CAV:CAL_SCALE and beam-based FUDG scale factor.
  
  
 Chassis and ADC scale factor, or polynomial coefficients. From lab measurements of chassis to convert ADC units to physics units
 PI(no D) loop parameters for amplitude and phase loops. Maybe PKp, PKi, GKp, GKi
 Open loop amplitude and phase DAC settings
 Control loop status (open, closed)
  
  

...