Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

 NameDescription
 GDESOperation Gradient setpoint (MV/m)
 GACTMeasured gradient from cavity probe (MV/m)
 GMAX

Maximum allowable gradient (MV/m)

 GCALGradient calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output.
 ADESOperation Amplitude setpoint (MV)
 AACTMeasured amplitude from cavity probe (MV)
 AMAX

Maximum allowable amplitude (MV)

 ACALAmplitude calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output.
 PDESOperation Phase setpoint (degrees, where 0 is on-crest)
 PACTMeasured phase from cavity probe (degrees)
 PREFa.k.a.gold, phase offset used by LLRF to convert measured phase to one relative to on-crest operation, adjusted by beam phasing (detrees)
 FDESCavity detuning setpoint (Hz)
 FACTDetune seen by the resonance system (Hz)
 ModeRF mode (off, pulsed, SEL, GDR)
 RFCTRLMaster enable for an RF cavity (On, Off) \[How to distinguish this from the SSA specific RF enable register?]
 RFReadyStatus of RF controls, (Ready, Not Ready) set to ready when control loops are closed and RF is continuous. Or will we ever run with pulsed RF?
 QuenchStatus showing when a cavity quenches, from interlocks (Normal, Quenched)
 STATStatus bits in software (define the bits)
 HSTAHardware status
 GTRACEGradient waveform from the cavity probe, which is used to calculate GACT (MV/m)
 PTRACEPhase waveform from the cavity probe, which is used to calculate PACT (degrees)
 *ERRTRACEError waveforms corresponding to waveforms above, captured and put in a separate buffer when a fault is detected (degrees or MV/m)
  Any of the above in I/Q equivalent of Amplitude/Phase
 PwrFwdForward power from SSA to cavity
 PwrRevReflected/reverse power from cavity
 PzWFWaveforms from tuner piezo motors, useful for finding microphonics. Units TBD.
 ALEMLEM computed integrated RF amplitude (MV) per cavity and per cryomodule
 PLEMLEM computed phase (deg)
 EGLEMLEM computed energy gain (MeV)
 CHLEMLEM computed chirp (MeV)
  Waveform Signals

The PVs below will be provided for each waveform signal. Each cavity has the following waveform signals:

Description PV name, <SIG> in following section
 Drive DRV
 Forward Power FWD
 Reflected Power REV
 Cavity Probe CAV
 Detune DET
 DAC (FPGA internal, input to DAC that drives SSA) DAC
 Waveform <SIG>:ATRACE Signal amplitude waveform

 Statistics   

 <SIG>:AMEAN Mean of <SIG>:ATRACE
 <SIG>:ASTD Standard deviation of <SIG>:ATRACE
 <SIG>:AMIN Minimum of <SIG>:ATRACE
 <SIG>:AMAX Maximum of <SIG>:ATRACE
 Waveform <SIG>:PTRACE Signal phase waveform
 Statistics     <SIG>:PMEAN Mean of <SIG>:PTRACE
 <SIG>:PSTD Standard deviation of <SIG>:PTRACE
 <SIG>:PMIN Minimum of <SIG>:PTRACE
 <SIG>:PMAX Maximum of <SIG>:PTRACE
 Waveform <SIG>:PWRTRACE Signal power waveform
 Statistics     <SIG>:PWRMEAN Mean of <SIG>:PWRTRACE
 <SIG>:PWRSTD Standard deviation of <SIG>:PWRTRACE
 <SIG>:PWRMIN Minimum of <SIG>:PWRTRACE
 <SIG>:PWRMAX Maximum of <SIG>:PWRTRACE
 Waveform <SIG>:ITRACE Signal I waveform