Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • All fields are required to be Upper Case characters the the exception of the Attribute field which is allowed to be mixed case with the following constraints.
    • There must be zero requirements for access to the PV from the SLC Control System (SCP). The SLC Control System is case insensitive and will be unable to read the mixed case PVs.
    • Is it strongly suggested that UpperCamelCase* be used for mixed case, however all uppercase still should be used as much as possible when creating new PV names. We realize that when we bring in support from other labs, the case may have a different format, but all PVs names that we create should either be all upper case or UpperCamelCase .
    • The attribute part of the name is the only part that is allowed to have mixed case, device, area, and unit number fields are still required to be all upper case.
    • It is not allowed to have different PVs which only differ in case.
  • The entire name is currently restricted to 28 characters or less.
  • The DeviceType is between 3 and 9 characters in length. The generic type of device is denoted by 3 or 4 characters, and may optionally be followed by an underscore with 3 or 4 more characters to indicate details of that device.
  • The Area field is 4 characters in length, and describes one of the 21 areas currently in the LCLS Accelerator.
  • The Position field can be up to 4 characters in length, which includes either an optional 1-character position prefix followed by 3 digits (for devices associated with the beam line) or 2-character prefix followed by an index for non-beam-line devices which are itemized.
  • The Attribute field must be 12 characters or less.
  • All PV names must be unique in the control system. This includes being unique across machines such as LCLS, SLC, FACET, FACET-II, and LCLS-II.

The optional fields are meant to accommodate the SLC-Aware IOC mechanism, which has even more restrictions placed on Device names. For more information, from the original Naming Convention plans, click here.

...

Table 1.10

Area

Physical Location

Access Buildings

ACR0

Accelerator Control Room (B052)

B005

Building 5

B24

Building 24  (development)

B25

Building 25  (development)

B34

Building 34  (development)

B44

Building 44 - Klystron Test Lab

B81

Building 81 - MMF 

B106

Building 106

B106

Building 136

B911

Building 911

B911

Building 911

B911

Building 911

B921

Building 921

ASTA-UED Facility Area

AS01

Accelerator Structure Test System

Injector Machine Areas

LR10

FACET-II Laser Room (Upstairs, near sector 10)

LR20

LCLS Laser Room (Upstairs, near sector 20)

LA20

FACET Laser Room (Upstairs, near Sector 20)

IN10

FACET-II Injector

IN20

LCLS Injector

LINAC Areas

LI00

LINAC Sector 0

LI20

LINAC Sector 20

LI21

LINAC Sector 21

LI22

LINAC Sector 22

LI23

LINAC Sector 23

LI24

LINAC Sector 24

LI25

LINAC Sector 25

LI26

LINAC Sector 26

LI27

LINAC Sector 27

LI28

LINAC Sector 28

LI29

LINAC Sector 29

LI30

LINAC Sector 30

Beam Switch Yard

For the entire beam switch yard area spanning from the wooden door to the Muon Shield, the device

positions shall range from 100-999, consistently across all beam lines, such that the unit numbers

 match up in Z-position across all beam lines.

MCC0

Main Control Center (B005) OBSOLETE. Replaced with ACR0

CLTH

Copper LINAC to Hard Line

CLTS

Copper LINAC to Soft Line

BSYH

Beam Switch Yard Hard Line

BSYS

Beam Switch Yard Soft Line

BSYA

Beam Switch Yard A-Line

SLTH

Superconducting LINAC to Hard Line

SLTS

Superconducting LINAC to Soft Line

SLTD

Superconducting LINAC to Dump Line

BSYS

Beam Switch Yard South Arc

LINAC to Undulator Machine Areas

LTU0

LINAC-to Undulator directly after BSY

LTU1

LINAC-to-Undulator Line 1

Undulator

UND1

Undulator on Line 1

Dump

DMP1

Beam Dump on Line 1

Photon Areas

FEE1

Front End Enclosure on Line 1

NEH1

Near Experimental Hall on Line 1

XRT1

X-Ray Tunnel on Line 1

FEH1

Far Experimental Hall on Line 1

XTA Facility Area

XT01

X-Band Test Area

Global Areas 

SYS0

LCLS-I System

SYS1

FACET and FACET-II System

SYS2

LCLS-II System

SYS3

LCLS-III System

SYS4

NLCTA System

SYS5

SPEAR Systems

SYS6

X-Band Test Area

SYS7

ASTA Test Area

SYS8

 Klystron Test Lab (B44)

SYSW

Global System West

SYSE

Global System East

GBL0

Global to all Machines

...

Table 1.11

Area

Position Prefix Codes

Physical Position

LR20

L

Laser Room (Upstairs, near sector 20)

 

IN20

B

Beam Line

 

K

Klystron Gallery

 

W

Waveguide

 

R

RF Equipment Hut

 

L

Laser Line

 

M

Manifold

 

LI20

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI21

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI22

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI23

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI24

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI25

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI26

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI27

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI28

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI29

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

LI30

B

Beam Line

 

W

Waveguide

 

K

Klystron Gallery

 

M

Manifold

 

E

Instrumentation Equipment Alcove

 

BSY0

B

Beam Line

 

E

Surface Equipment Building (Bldg 136, 106, 106, 5)

 

P

BSY Pump Station (P0, P1, P2, P3, P5)

 

 

BSYA

B

Beam Line

 

E

Surface Equipment Building (Bldg 136, 106, 106, 5)

 

P

BSY Pump Station (P0, P1, P2, P3, P5)

 

 

BSYB

B

Beam Line

 

E

Surface Equipment Building (Bldg 136, 106, 106, 5)

 

P

BSY Pump Station (P0, P1, P2, P3, P5)

 

 

BSYN

B

Beam Line

 

E

Surface Equipment Building (Bldg 136, 106, 106, 5)

 

P

BSY Pump Station (P0, P1, P2, P3, P5)

 

BSYS

B

Beam Line

 

E

Surface Equipment Building (Bldg 136, 106, 106, 5)

 

P

BSY Pump Station (P0, P1, P2, P3, P5)

 

LTU0

B

Beam Line

 

E

Surface Equipment Building (Bldg 5 or 911)

 

LTU1

B

Beam Line

 

E

Surface Equipment Building (Bldg 105 or Bldg 406 or

 

 

Bldg 911 or Bldg 912 or Bldg 913)

 

MCC0

E

Equipment Rack Area (Bldg 5) OBSOLETE

 

C

Control Room

 

UND1

B

Beam Line

 

E

Surface Equipment Building (Bldg 913,921)

 

DMP1

B

Beam Line

 

E

Surface Equipment Building (Bldg B921)

 

FEE1

B

Beam Line

 

 

Hard (High-energy) through Branch (South) to Hutch 3 and beyond

 

1

Soft (Low-energy) Branch (North) to Hutch 1

 

2

Soft (Low-energy) Branch (Middle) to Hutch 2

 

E

Equipment Rack Alcove or Surface Equipment Building (Bldg 940)

 

NEH1

B

Beam Line

 

 

Hard (High-energy) Branch (South) to Hutch 3 and beyond

 

1

Soft (Low-energy) Branch (North) to Hutch 1

 

2

Soft (Low-energy) Branch (Middle) to Hutch 2

 

E

Surface Equipment Building (Bldg 950)

 

XRT1

B

Beam Line

 

 

Through Branch

 

4

North Branch to Hutch 4

 

5

Middle Branch to Hutch 5

 

6

South Branch to Hutch 6

 

E

Surface Equipment Building (Bldg 960)

 

FEH1

B

Beam Line

 

4

North Branch to Hutch 4

 

5

Middle Branch to Hutch 5

 

6

South Branch to Hutch 6

 

E

Surface Equipment Building (Bldg 999)

XT01

B

Beam Line

 

 

Surface Equipment Building (Bldb 062)

SYS0

 

LCLS-I System

SYS1

 

FACET and FACET System-II System

SYS2

 

LCLS-II System

SYS3

 

LCLS-III System

SYS4

 

NLCTA System

SYS5

 

SPEAR System

SYS6

 

X-Band Test Area

SYS7

 

ASTA Test Area

SYS8

 

Klystron Test Lab (B44)

SYSW

 

Global System West

SYSE

 

Global System East

GLB0

 

Global to all Machines

...