Search/Navigation:
Related:
SLAC/EPP
/HPS Public
Jefferson Lab/Hall B
/HPS Run Wiki
S30XL-LESA/LDMX
Table as of 11/17/2014
GUI FEB ID | Physical FEB | Status | Comment |
---|---|---|---|
0 | L1t | OK | |
1 | L2-3t | OK | |
2 | L5t | OK | |
3 | L6t | OK | |
4 | L4t | OK | |
5 | L4b | OK | |
6 | L5b | OK | |
7 | L6b | OK | |
8 | L2-3b | OK | |
9 | L1b | OK |
GUI Flange ID | Physical Flange Board | Status |
---|---|---|
0 | 1 (top) | OK |
1 | 2 | OK |
2 | 3 | OK |
3 | 4 (bottom) | OK |
Typically after a reboot we need to reload the pgp card driver.
$ cd /u1/pgpcard/software/driver_old/
$ ./pgpcard_load
Start the DAQ:
$ cd /u1/software/software_new
...
Check that the hybrid currents measured are ok. Sync status for each channel can be seen in register RceCore/DataPath[x]/Synced, 1xf for powered channels.