Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migration of unmigrated content due to installation of a new plugin

...

Examples of a device name would look as follows:

{:sortColumn=1|sortIcon=true|border=0|align=center|cellspacing=0|cellpadding=10|class=''|title='Example Device Types'|highlightColor=white|bgcolor=silver|columnTypes=|columnAttributes=
Wiki Markup
Advanced Tables - Table Plus
border0
highlightColorwhite
sortColumn1
bgcolorsilver
columnTypes
S,F,F,F
cellpadding10
cellspacing0
columnAttributesfont-size:12pt;
text-align:
center;"
aligncenter
title'Example Device Types'
class''
sortIcontrue
} || *Device Type* || *Nodename* || | Access Switch |

Device Type

Nodename

Access Switch

ACSW-IN20-NW01

| |

Terminal

Server

|

TS-IN20-NW01

| |

Magnet

IOC

|

IOC-IN20-MG01

| {table-plus}

...

The Device Type Field


Wiki Markup
{center}{*}Table 1.0{*}{center}

...

{:sortColumn=1|sortIcon=true|border=0|align=center|cellspacing=0|cellpadding=10|class=''|title='Device Types Field'|highlightColor=white|bgcolor=silver|columnTypes=|columnAttributes=
Advanced Tables - Table Plus
border0
highlightColorwhite
sortColumn1
bgcolorsilver
columnTypes
S,F,F,F
cellpadding10
cellspacing0
columnAttributesfont-size:12pt;
text-align:
center;"
aligncenter
title'Device Types Field'
class''
sortIcontrue

Device Type

Description

Manufacturer

Model

ACSW

AC Switch

 

 

CHAS

Chassis

 

 

GPIB

GPIB/LAN Gateway

 

 

DDM

Digital Multimeter

Keithley

2701

RTR

Router

Cisco

 

SWH

Ethernet Switch

CISCO

 

TS

Terminal Server

DIGI

DIGI-TS16

UPS

Uninterruptible Power Supply

APS

 

WKUP

Walk-up ethernet connection

 

 

EIOC

Embedded IOC

NetBurner,Arcturus

Coldfire 5282, MicroC5282

IOC

IOC

Motorola

MVME6100

SIOC

Soft IOC

Linux Host

 

VIOC

Virtual IOC (Process)

 

 

CPU

Central Processing Unit

 

PLC

Programmable Logic Controller

Allen-Bradley,Pils

 

PSC

Ethernet Power Supply Controller

SLAC (Dave MacNair)

EPSC

CAMR

Camera for Beam Line Optics

Pulnix

 

CRAT

Intelligent VME Crates

Wiener/Dawn

 

MET

Metrology

 

 

INST

Instrument

 

 

} || *Device Type* || *Description* || *Manufacturer* || *Model* || | ACSW | AC Switch | | | | CHAS | Chassis | | | | GPIB | GPIB/LAN Gateway | | | | DDM | Digital Multimeter | Keithley | 2701 | | RTR | Router | Cisco | | | SWH | Ethernet Switch | CISCO | | | TS | Terminal Server | DIGI | DIGI-TS16 | | UPS | Uninterruptible Power Supply | APS | | | WKUP | Walk-up ethernet connection | | | | EIOC | Embedded IOC | NetBurner,Arcturus | Coldfire 5282, MicroC5282 | | IOC | IOC | Motorola | MVME6100 | | SIOC | Soft IOC | Linux Host | | | VIOC | Virtual IOC (Process) | | | | CPU | Central Processing Unit | | | PLC | Programmable Logic Controller | Allen-Bradley,Pils | | | PSC | Ethernet Power Supply Controller | SLAC (Dave MacNair) | EPSC | | CAMR | Camera for Beam Line Optics | Pulnix | | | CRAT | Intelligent VME Crates | Wiener/Dawn | | | MET | Metrology | | | | INST | Instrument | | | {table-plus}

...

The Area Field


The Area field is 4 characters in length. There are currently 24 areas in the LCLS Accelerator. Going from the Drive Laser to the Experimental areas they include:

Wiki Markup
{center}{*}Table 1.1{*}{center}

...

{:=0|sortColumn=1|sortIcon=true|align=center|cellspacing=0|cellpadding=10|class=''|title='Area Field'|highlightColor=white|bgcolor=silver|columnTypes=|columnAttributes=
Advanced Tables - Table Plus
border
0
highlightColorwhite
sortColumn1
bgcolorsilver
columnTypesS,F,F,F
cellpadding10
cellspacing0
columnAttributesfont-size:12pt;
text-align:
center;"
aligncenter
title'Area Field'
class''
sortIcontrue

Area

Physical Location

LR20

Laser Room (Upstairs, near sector 20)

IN20

Injector

LI20

LINAC Sector 20

LI21

LINAC Sector 21

LI22

LINAC Sector 22

LI23

LINAC Sector 23

LI24

LINAC Sector 24

LI25

LINAC Sector 25

LI26

LINAC Sector 26

LI27

LINAC Sector 27

LI28

LINAC Sector 28

LI29

LINAC Sector 29

LI30

LINAC Sector 30

MCC0

Main Control Center (Bulding 005)

BSY0

Beam Switchyard

BSYS

Beam Switch Yard South

BSYN

Beam Switch Yard North

LTU0

LINAC-to Undulator Switchyard

LTU1

LINAC-to-Undulator Line 1

UND1

Undulator on Line 1

DMP1

Beam Dump on Line 1

FEE1

Front End Enclosure on Line 1

NEH1

Near Experimental Hall on Line 1

XRT1

X-Ray Tunnel on Line 1

FEH1

Far Experimental Hall on Line 1

SYS0

System

} || *Area* || *Physical Location* || | LR20 | Laser Room (Upstairs, near sector 20) | | IN20 | Injector | | LI20 | LINAC Sector 20 | | LI21 | LINAC Sector 21 | | LI22 | LINAC Sector 22 | | LI23 | LINAC Sector 23 | | LI24 | LINAC Sector 24 | | LI25 | LINAC Sector 25 | | LI26 | LINAC Sector 26 | | LI27 | LINAC Sector 27 | | LI28 | LINAC Sector 28 | | LI29 | LINAC Sector 29 | | LI30 | LINAC Sector 30 | | MCC0 | Main Control Center (Bulding 005) | | BSY0 | Beam Switchyard | | BSYS | Beam Switch Yard South | | BSYN | Beam Switch Yard North | | LTU0 | LINAC-to Undulator Switchyard | | LTU1 | LINAC-to-Undulator Line 1 | | UND1 | Undulator on Line 1 | | DMP1 | Beam Dump on Line 1 | | FEE1 | Front End Enclosure on Line 1 | | NEH1 | Near Experimental Hall on Line 1 | | XRT1 | X-Ray Tunnel on Line 1 | | FEH1 | Far Experimental Hall on Line 1 | | SYS0 | System | {table-plus}

...

The Subsystem Prefix Field

...

Wiki Markup
{center}{*}Table 1.2{*}{center}

...

{:sortColumn=1|sortIcon=true|border=0|align=center|cellspacing=0|cellpadding=10|class=''|title='Subsystem Prefix Field'|highlightColor=white|bgcolor=silver|columnTypes=|columnAttributes= } || *Subsystem Prefix* || *Subsystem* || | LS | Laser Steering | | PM | Profile Monitor | | SP | Spectrometer | | IM | Current Monitor | | BL | Bunch Length Monitor | | BP | Beam Position Monitor | | MC | Motion Control | | CL | Collimator | | AM | Alignment Mirror | | AL | Alarm Handler | | LG | Data Logger | | MG | Magnet | | EV | Event | | RF | Low-Level RF (LLRF) | | KY | Klystron | | MP | Machine Protection System (MPS) | | NW | Network Device, terminal servers, switches routers | | PP | Personnel Protection System (PPS) | | BC | Beam Containment System (BCS) | | TM | Temperature Monitor | | TR | Toroid | | VA | Vacuum | | WS | Wire Scanner | | FB | Beam-based Feedback | {table-plus}
Advanced Tables - Table Plus
border0
highlightColorwhite
sortColumn1
bgcolorsilver
columnTypes
S,F,F,F
cellpadding10
cellspacing0
columnAttributesfont-size:12pt;
text-align:
center;"
aligncenter
title'Subsystem Prefix Field'
class''
sortIcontrue

Subsystem Prefix

Subsystem

LS

Laser Steering

PM

Profile Monitor

SP

Spectrometer

IM

Current Monitor

BL

Bunch Length Monitor

BP

Beam Position Monitor

MC

Motion Control

CL

Collimator

AM

Alignment Mirror

AL

Alarm Handler

LG

Data Logger

MG

Magnet

EV

Event

RF

Low-Level RF (LLRF)

KY

Klystron

MP

Machine Protection System (MPS)

NW

Network Device, terminal servers, switches routers

PP

Personnel Protection System (PPS)

BC

Beam Containment System (BCS)

TM

Temperature Monitor

TR

Toroid

VA

Vacuum

WS

Wire Scanner

FB

Beam-based Feedback

...

{table-plus}{table-plus}
Advanced Tables - Table Plus
Wiki Markup