CU ACD have basically two calibration parameters for each channel (PMT), 6 in total - MIP peak position and pedestal (both - in ADC bins). Calibration parameters for PS obtained in the 5 GeV pions runs on July 29, are given in the attachment. These parameters are preliminary and are subject for the revision. Please use them with caution.

 Calibration parameters for SPS runs, obtained in pion runs 700001865-700001871 are given in table below. Explanation of Tile 3 is given in the attachment "ACD_Tile_3_calibration.doc"

 

Tile Physical #

Tile Recon Id

Pedestal

MIP peak, pedestal removed

0

130

140

1396

1

120

141

1928

2

110

167

908

3A

100A

1033

Use combination 1.3*PMT_A+PMT_B
with MIP peak at 1623

3B

100B

567

4

0

212

492