Code Block |
---|
ipmitool-pps -I lan -H <shelfmanager> -t <COB Address> -b 0 -A NONE raw <SLAC_NETFN> <CMD> [DATA_0] [DATA_1] ... [DATA_N]
Where:
<shelfmanager> is the hostname/IP address of the Shelf Manager (ex. shasta-sm)
<COB address> is the IPMB address of the COB board (ex. 0x82, 0x84, 0x86, 0x88, 0x8a)
<SLAC_NETFN> The NetFn for our custom command extensions which is 0x34
<CMD> [DATA_X] is the command to be issued and associated parameter as described below
or in the IPMC console window:
[D0 00 <CMD> [DATA_0] [DATA_1] ... [DATA_N]]
Write to Cluster Element BSI: <CMD> = 0x03
The format for this command is
Offset Length Description
0 1 BAY Mask
1 1 RCE Mask
2 1 Do interrupt (Does Nothing)
3 2 Address
5 2 Length to write
7 N Data to write (if length < 16)
(if length > 16, fill with
incrementing data starting with data)
NOTE: Including Bays w/o RCEs or which are not present
in BAY Mask will not result in an error.
Similarly, including RCEs which are not present or are
currently being reset will not result in an error, nor
will RCEs currently held in reset be released from reset
as a result of issuing this command.
Read from Cluster Element BSI: <CMD> = 0x4
The format for this command is
Offset Length Description
0 1 BAY Number
1 1 RCE Number
2 2 Address
4 2 Length to read (Though 2 bytes long, IPMI practically limits this to <16)
Read COB Data Board ID PROM: <CMD> = 0x5
The format for this command is
Offset Length Description
0 1 BAY Number
Returns the ID
0 6 MSB -> LSB 6 byte ID
Set Monitor Dump Period: <CMD> = 0x07
The format for this command is
Offset Length Description
0 1 Dump Index [0=BAY, 1=RCE, 2=BSI, 3=SFP, 4=FP_DISP, 5=BAY_GPIO, 6=BAY_GPIO_FULL, 7=RTM, 8=CEN]
1 2 Seconds [0=Never Dump, 0xffff=Default]
Get Monitor Dump Period: <CMD> = 0x08
The format for this command is
Offset Length Description
0 1 Dump Index [0=BAY, 1=RCE, 2=BSI, 3=SFP, 4=FP_DISP, 5=BAY_GPIO, 6=BAY_GPIO_FULL, 7=RTM, 8=CEN]
Returns
0 2 Seconds [0=Never Dump]
Monitor Dump Immediate: <CMD> = 0x09
The format for this command is
Offset Length Description
0 1 Dump Index [0=BAY, 1=RCE, 2=BSI, 3=SFP, 4=FP_DISP, 5=BAY_GPIO, 6=BAY_GPIO_FULL, 7=RTM, 8=CEN]
RCE Reset Command: <CMD> = 0x0A
The format for this command is
Offset Length Description
0 1 BAY Mask
1 1 RCE Mask
This command returns
Offset Length Description
0 1 Completion Code
1 1 Mask of Bays with errors
NOTE: Including Bays w/o RCEs or which are not present
in BAY Mask will not result in an error.
Similarly, including RCEs which are not present or are
currently being reset will not result in an error, nor
will RCEs currently held in reset be released from reset
as a result of issuing this command.
Read from RTM EERPOM: <CMD> = 0x0B
The format for this command is
Offset Length Description
0 1 EEPROM Select (0=RTM Fru Info EEPROM, 1=RMB EEPROM)
1 1 Address
2 1 Length to read (Limited by IPMI to 24 bytes)
Write to RTM EERPOM: <CMD> = 0x0C
The format for this command is
Offset Length Description
0 1 EEPROM Select (0=RTM Fru Info EEPROM, 1=RMB EEPROM)
1 1 Address
2 1 Length to write
3 N Data to write (Limited by IPMI to 22 bytes)
Set Refresh Shelf Info: <CMD> = 0x0d
The format for this command is
Offset Length Description
N/A N/A There are no arguments to this command
Get Bay Power Command: <CMD> = 0x0E
The format for this command is
Offset Length Description
0 1 The BAY number
This command returns
Offset Length Description
0 1 Completion Code
1 2 Voltage in mV (ADIN)
3 2 Current in mA
Get Bay Temperatures: <CMD> = 0x0F
The format for this command is
Offset Length Description
0 1 BAY number
1 1 RCE number (optional)
This command returns
Offset Length Description
0 1 Completion Code
1 1 Board Temperature
2 1 Junction Temperature
Set FP SFP Switch Group: <CMD> = 0x10
The format for this command is
Offset Length Description
0 1 SFP+ Mask
1 1 Group Number 0x00 = No Group
0x01 - 0x10 Group with Slot at Physical address 0x01 - 0x10
0x11 - 0xFF Arbitrary Group Numbers
Set Standalone Slot Number: <CMD> = 0x11
The format for this command is
Offset Length Description
0 1 Slot Number
I2C Read: <CMD> = 0xF7
Low level I2C Read
The format for this command is
Offset Length Description
0 1 I2C Bus
1 1 Device Address (8 bit address)
2 1 Length to read
This command returns
Offset Length Description
0 1 Completion Code
1 N Data read
I2C Write: <CMD> = 0xF8
Low level I2C Write
The format for this command is
Offset Length Description
0 1 I2C Bus
1 1 Device Address (8 bit address)
2 1 Length to write
3 N Data to write
This command returns
Offset Length Description
0 1 Completion Code
Cold Data Reset: <CMD> = 0xF9
The Cold Data Reset command will reset the IPMC and mark the
Cold Data Journal as invalid. This mimics removing power from the IPMC.
Set Zombie RCE: <CMD> = 0xFA
When an RCE is marked as a Zombie, the IPMC will not allow it to hold up the booting of the board.
(For example, it will mark the switch port configuration in the DTM BSI as "Disabled"
if the DPM is not Ready.
The format for this command is
Offset Length Description
0 1 Bay Number
1 1 RCE Number
2 1 Zombie State [0=Not a Zombie, 1=BRAINS!]
Set Bay Power: <CMD> = 0xFB (This is only intended to be used for HW debugging as immediately turns on/off power to a Bay.)
The format for this command is
Offset Length Description
0 1 BAY MASK
|
Supported IPMI/ATCA commands
...