This must be done separately for the three subsystems (ACD, CAL, TKR) . so one has to look at the three relative tab widgets.
- ACD: this is done through the ACD tab in the Run Control main GUI. A text label on the right end of the tab notify the status of the high voltage.
- CAL: this is done through the CAL tab in the Run Control main GUI. There's a button at the bottom of the tab for refreshing the BIAS DAC setting. The nominal value should be 0x5800.
- TKR: this is done through the TKRtab in the Run Control main GUI. There's a button for refreshing the level of the TKR bias voltage. The nominal value shuold be around 100 V.
Again: under normal conditions the bias voltages to the detectors should be on all the times and the shifters should not have to turn it on/off manually.
Selecting an application
e2eBT
Starting a run