Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Panel
Wiki Markup

h1. LCLS Network Node Naming Conventions




[LCLS NamingConventions|LCLS Naming Conventions]
[LCLS Network|Network]
[SCCS Computer Account Forms|http://www2.slac.stanford.edu/comp/slacwide/account/account.html]
[How-to Setup DHCP for an IOC|How-to Setup DHCP for an IOC]



Network node names are meant to be consistent with the overall device [LCLS Naming Conventions]. One exception is that the fields of the PV name are separated by a "-" whereas the fields of a node name is separated by a ":". In addition, node names are in lower case, whereas PV names are all uppercase, due to SLC Controls System restrictions on VMS. A limitation of 24-characters is also current inforced due to a restriction on the VMS EPICS Channel Access Server.

The network node name conforms to the following format: <*Device Type* ><*Area* ><*Position*>

The _DeviceType_ Field for network devices is 2-4 characters in length and can be found in the Table 1.0. The _Area_ Field is 4-character field, with numbers and letters and can be found in Table 1.2. The _Position_ Field contains a 2-character, a _Subsystem Prefix_, followed by a 2-digit _Index_ from 01 to 99.  The Prefix designates a subsystem of the control system as follows in Table 1.2.

Examples of a device name would look as follows:
{table-plus:sortColumn=1|autoNumber=true|sortIcons=trueborder=0|align=center|cellspacing=0|cellpadding=10|class=''|title='Example Device Types'|
            highlightColor=white|bgcolor=silver|columnTypes=S,F,I,I}



F,F|
            columnAttributes=style="background:yellow; font-size:12pt; text-align: center;"}
|| *Device Type* || *Nodename* ||
|| Access Switch | ACSW-IN20-NW01 ||
|| Terminal Server | TS-IN20-NW01 ||
|| Magnet IOC | IOC-IN20-MG01 ||
{table-plus} \|
\\
To obtain an ip address for an LCLS device click [here|http://www2.slac.stanford.edu/computing/helpdesk/ipaddform_r1.htm] for SCCS IP/Node Name Request form. Fill out this form according the the naming conventions described herein and email this information to [Charlie Granieri|http://www-public.slac.stanford.edu/phonebook/dirsearch.aspx?lf=1&url=&gone=active&NAME=granieri].
\\
\\

h2. The Device Type Field\\


\\
\|
| *Table 1.0* |
| *Device Type* | *Description* | *Manufacturer* | *Model* | {SORT(sort=>asc)}| ACSW | AC Switch | | |
| GPIB | GPIB/LAN Gateway | | |
| DDM | Digital Multimeter | Keithley | 2701 |
| RTR | Router | Cisco | |
| SWH | Ethernet Switch | CISCO | |
| TS | Terminal Server | DIGI | DIGI-TS16 |
| UPS | Uninterruptible Power Supply | APS | |
| WKUP | Walk-up ethernet connection | | |
| EIOC | Embedded IOC | NetBurner,Arcturus | Coldfire 5282, MicroC5282 |
| IOC | IOC | Motorola | MVME6100 |
| SIOC | Soft IOC | Linux Host |
| PLC | Programmable Logic Controller | Allen-Bradley,Pils | |
| PSC | Ethernet Power Supply Controller | SLAC (Dave MacNair) | EPSC |
| CAMR | Camera for Beam Line Optics | Pulnix | |
| CRAT | Intelligent VME Crates | Wiener/Dawn | |
| MET | Metrology | | |
| INST | Instrument | | |
|| {SORT}\\
h2. The Area Field\\
 \\
The _Area_ field is 4 characters in length. There are currently 24 areas in the LCLS Accelerator.  Going from the Drive Laser to the Experimental areas they include:\| *Table 1.1* \| Area || Physical Location ||
| LR20 | Laser Room (Upstairs, near sector 20) |
| IN20 | Injector |
| LI20 | LINAC Sector 20 |
| LI21 | LINAC Sector 21 |
| LI22 | LINAC Sector 22 |
| LI23 | LINAC Sector 23 |
| LI24 | LINAC Sector 24 |
| LI25 | LINAC Sector 25 |
| LI26 | LINAC Sector 26 |
| LI27 | LINAC Sector 27 |
| LI28 | LINAC Sector 28 |
| LI29 | LINAC Sector 29 |
| LI30 | LINAC Sector 30 |
| MCC0 | Main Control Center (Bulding 005) |
| BSY0 | Beam Switchyard |
| LTU0 | LINAC-to Undulator Switchyard |
| LTU1 | LINAC-to-Undulator Line 1 |
| UND1 | Undulator on Line 1 |
| DMP1 | Beam Dump on Line 1 |
| FEE1 | Front End Enclosure on Line 1 |
| NEH1 | Near Experimental Hall on Line 1 |
| XRT1 | X-Ray Tunnel on Line 1 |
| FEH1 | Far Experimental Hall on Line 1 |
| SYS0 | System | \\
h2. The Subsystem Prefix Field\\
 \\ |
| *Table 1.2* |
| *Subsystem Prefix* | *Subsystem* |{SORT(sort=>asc)} |
| LS | Laser Steering |
| PM | Profile Monitor |
| SP | Spectrometer |
| IM | Current Monitor |
| BL | Bunch Length Monitor |
| BP | Beam Position Monitor |
| MC | Motion Control |
| CL | Collimator |
| AM | Alignment Mirror |
| AL | Alarm Handler |
| LG | Data Logger |
| MG | Magnet |
| EV | Event |
| RF | LLRF |
| MP | MPS |
| NW | Network Device, terminal servers, switches routers |
| PP | PPS |
| BC | BCS |
| TM | Temperature Monitor |
| TR | Toroid |
| VA | Vacuum |
| WS | Wire Scanner |
| FB | Beam-based Feedback | {SORT} |