Things to check: | 3/2/24 outage | System owner: | Notes: | |
---|---|---|---|---|
Oven mover is in bypass position |
| Doug S. | Required to clear MPS fault. | |
Retract the DS Be window | Doug S. / Ivan | |||
PB, spectrometer, and laser transport turbos on | Doug S. / Ivan | |||
When LCW is off: Ensure beamline valves inserted, DPS turbos and roughing pumps are OFF. | Doug S. | |||
When LCW is back on: DPS pumps restarted (US and DS turbos and roughing pumps).
| Ops / Doug S. | DS Be window should be retracted first | ||
DPS Vacuum watcher restarted | Ops / Doug S. | |||
Spectrometer Camera Checkout Procedure | Doug S. | |||
IP flippers are checked and are in a safe state | ||||
Motor reinitialisation: Most motors are homed, a few are postponed to next PAMM (see: here) | ||||
Alignment laser can transmit through IP into IPTOR1. IPOTR2 → Camera problems, DSOTR→ Motor issues (catered) |