The multiple scattering plot fit gives: x/x0 = 2.94 +- 0.03

The (rescaled) momentum resolution fit gives a constant value: c = (1.395 +- 0.007)%

Notice that some of the runs have a different magnet current (this is necessary if we don't change the geometry), but, after rescaling the resolution so a rescaling to the same bending power we observeis needed.

The (rescaled) momentum resolution fit gives a constant value: c = (1.395 +- 0.007)%
 

 
 

 The momentum resolution, at different bending power, can be evalueted with:

No Format
dp/p(%) = c*BL_max/BL = 1.395*0.7089/BL

 

 

 

...

Image Added

Here is a table of calculated tagger resolution for particular current settings:

Current (A)

dp/p (%)

100

8.1092

120

6.7661

150

5.42303

180

4.52769

200

4.08003

220

3.71378

240

3.40858

250

3.27429

300

2.73719

350

2.35359

360

2.28966

400

2.06593

420

1.97006

450

1.84223

500

1.66331

550

1.51695

600

1.39501

650

1.29186

700

1.20346

 Calibration of the bending magnet

...

No Format
B*L (T*m) = 0.0012271*I(A) - 7.60132e-08*I^2(A^2)

 

 

...

 
 

 Angular reconstruction

...