Power Estimation
Estimate: test run measured values
Nominal: APV25 current draw
Maximum: maximum from APV25 manual
System | Estimate (W) | Nominal (W) | Maximum (W) |
---|
FE Boards | 85 | 100 | 140 |
Hybrids | 75.6 | 140.4 | 298.8 |
Radiative load (from #1) | 9.4 | | 50 |
Simple estimate of radiative load on support plates
#1: Radiative load - Pelle
Requirements
- Temperature
- Sensor temperature -10C (support plate temperature approx. -20C)
- DAQ boards should be at room temperature at nominal power i.e. approx. +20C
- Mechanical
- Three cooling loops for DAQ (FE board support), L1-3 and L4-6 module support plates (no manifold inside vacuum box, for 2014 one 8" side flange of the vacuum box is available for cooling lines)
- Heat load
- 190W combined maximum heat load on L1-3 and L4-6 cooling
- 100W maximum heat load on DAQ cooling
Links
Hybrid power consumption
FE board power consumption