Purpose | Base PV | Connection | pmgr | python device | Cabled? | Verified/Homed? |
---|---|---|---|---|---|---|
Standard Motors | ||||||
MXI | ||||||
JJ Slits Not in questionnaire 4 motors | JJ Slits | MEC:TC1:MMS:[17,18] MEC:TC1:MMS:[01,02] | T5/2 and T5/8 |
Detectors Checklist (TBD)
MXI Hexapod | MEC:HEX:02 | Flange T3 to Hexapod 2 controller top of target chamber. | N/A | Yes | Yes | |
MXI linear stage | MEC:USR:MMS:21 | Micronix PPS-110 stage to Flange B7/H<tbd> to PR60 patch panel MEC:USR:MMS:21 connection | Crystal Y | |||
Zyla 500 mm linear stage | MEC:PPL:MMN:24 | In-air Direct cabling to XPS3, Card #8 | Newport | Yes | Yes |
Other Devices Checklist
Purpose | Base PV | Connection | Cabled? | Operational? |
---|---|---|---|---|
Permissive Signal | ||||
Trigger | MEC:USR:AIN:9 | User timing and firing unit permissive output (+5V 100 microsec pulse) to R62 EK9000, second KL3404 (card 11), first channel, PV MEC:USR:AIN:9. KL3404 specs are "4-channel analog input, voltage, ±10 V, 12 bit, single-ended" May need pulse extended, e.g. with a function generator, for detection by PLC. | Yes |
Detectors Checklist
Detector | DAQ alias | Connection | Cabled? | In DAQ? | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
epix10k-540k | quad_0
| in-air Power: Fiber: | |||||||||
epix10k-540k | quad_1 |
| epix10k-540k | quad_3 |
| ePix100 | SW Epix100a "epix100a_f" |
| in-air Power: Fiber: | ||
epix10k-549k | quad_2 | in-air Power: Fiber: | |||||||||
epix10k-540k | quad_3 | in-air Power: Fiber: | |||||||||
ePix100 | NE Epix100a "epix100a_b" |
| Andor Zyla | zyla | in-air USB/Fiber extender to daq-mec-cam02 | XRT spectrometer | hxsss | N/A | Yes | YesN/A |