Page History
...
plims panels/0000000001-0176294657-0218103830-1010951301-0019435010-0000000000-0000000000/gain/epix10ka_0069_20200915184723_mfxc00118_r0172_chi2ci_AHL-H.dat
plims panels/0000000001-0176294657-0218103830-1010951301-0019435010-0000000000-0000000000/gain/epix10ka_0069_20200915184723_mfxc00118_r0172_chi2ci_AHL-L.dat
plims panels/0000000001-0176294657-0218103830-1010951301-0019435010-0000000000-0000000000/gain/epix10ka_0069_20200915184723_mfxc00118_r0172_chi2ci_AML-L.dat
plims panels/0000000001-0176294657-0218103830-1010951301-0019435010-0000000000-0000000000/gain/epix10ka_0069_20200915184723_mfxc00118_r0172_chi2ci_AML-M.dat
chi2 for
...
AHL-H, AHL-L, AML-M, AML-L
panel 2
panel 2 tail of large values of chi2
panel 6
panel 6 tail of large values of chi2
Gain
Note |
---|
All single-panel gain is presented in raw units from the fit ADU/<event-number>. In combined for detector plots gain is derived from calibration constants normalized on Gabriel's gain factors in ADU/keV (factor of 3 smaller than raw). |
gain and negative tail for AML-L
panel 2
raw gain from fit in ADU/event
panel 6
raw gain from fit in ADU/event
WARNING: panel 6 one ASIC gain is almost twice smaller than ion other 3 ASICS ... we replace it by constant 0.164 ADU/keV, see Gain factors from Gabriel
gain for
...
AHL-H, AHL-L, AML-M, AML-L
panel 6
raw gain from fit in ADU/event
panel 2
raw gain from fit in ADU/event
other panels vertically jammed on a single plot
normalized gain in ADU/keV for AHL-H, AHL-L, AML-M, AML-L and AML-L negative tail
significant difference in ASIC gains is observed on panels 6 and 12
panel 12
AHL-L and AML-L
...
raw gain from fit in ADU/event
References
...