Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Context

TLDR

Photons of higher energies are generated by the undulators and needs to be blocked before they reach the interaction point (IP).

Details

The

More information about the HRM can be found here.

Context

In additional to the fundamental wavelength, the generation of x-ray by electron electrons passing through undulators also produces higher order radiation (produces, in addition of the fundamental energy, radiation at integer multiple of the fundamental energy, called harmonics. Because of symmetry, only the odd orders in fact). For are allowed, so for example, for a fundamental at 5keV, photons at 15keV, 25keV, etc. are also generated.

The intensity off of successive orders drops very quickly, but the 3rd harmonic is still intense enough to create spurious and unwanted signals. Because photons of higher energy penetrates more in materials, the rejection of these higher order is not straight-forward. This in fact make the problem worse if the attenuator is used, as the fundamental is more attenuated than the higher orders, hereby worsening the ratio of "good" photons to unwanted ones. Moreover, because they are multiple of the fundamental energy and thus share , they are shared similar diffraction conditions, and diffraction-based approach do not work.

...

Gliffy Diagram
macroId9f261fa5-e152-412c-a418-502192b07582
displayNameHRM
nameHRM
pagePin3


Screens

You can access motors relating to the HRM by clicking on the beamline related display (shown below).


Image Added

More information about the HRM can be found here.