PV Name | Purpose | EGU | Limits |
|
---|---|---|---|---|
KLYS_ LLRF:IN20:RH:LOB_PDES | Desired Phase used by LOB local feedback, users, apps other than beam-based feedback - may be used as readback by LEM | degrees; absolutefull range, not delta |
|
|
KLYS_ LLRF:IN20:RH:LOB_P | Desired Phase for Beam-based feedback only | degrees; absolutefull range | none provided- to be calculated by beam-based feedback |
|
KLYS_ LLRF:IN20:RH:L0B_PAVG | actual phase readback (avg of multiple channels): used by beam-based feedback, slc-aware readback arrys, | degrees; absolutefull range | none provided |
|
|
|
|
|
|
KLYS_ LLRF:IN20:RH:L0B_ADES | Desired Amplitude (or Power?) used by LOB local feedback, users, apps other than beam-based feedback - may be used as readback by LEM | MeV;full range volts; absolute | HOPR, LOPR |
|
KLYS_ LLRF:IN20:RH:L0B_A | Desired amplitude (or Power?) for beam-based feedback only | volts MeV; absolutefull range | HOPR, LOPR |
|
KLYS_ LLRF:IN20:RH:L0B_AAVG | actual amplitude readback (avg of multiple channels): used by beam-based feedback, slc-aware readback arrys, | volts MeV; absolutefull range | HOPR, LOPR |
|
|
|
|
|
|
KLYS_ LLRF:IN20:RH:G_L0_FB_CTL | When this in PV is ON, beam-based feedback locks out others users and other applications from setting L0B_A/P, or L0B_ADES/PDES and the local feedback is turned off. |
|
| |
|
|
|
|
|
NOTES
- These PV names and usages are a template for L1S and the BC1 energy beam-based feedback
- TBD: the The _A, _ADES, _AAVG may be power, not voltage - may need to use _V, _VDES, _VAVG
...
- give the absolute energy gain of an on-crest electron (they will be calibrated by some external means, mostly using the beam); the units of ADES will be MeV
- Phase _P, _PDES, _PAVG values give the absolute phase of the RF w.r.t. the beam (they are offset-corrected so that 0 means on-crest)
RESOLVED:
- The local feedback loops will remain on during beam-based feedback and other user or application inputs
- The Beam-based feedback takes precidence over local feedback other applications and user inputs. when Beam-based feedback is on, local feedback and user other inputs are disabled
UNRESOLVED:
- What to do with Local feedback when there are user inputs (such as correlation plots, etc)?
- TBD: the the L0B_A, _ADES, _AAVG may be power, not voltage - may need to use _V, _VDES, _VAVGL0B_P PVs will be an absolute value, not a delta.
- Both amplitude and phase will be available as an actuator for the Beam-based feedback for DL1. Only one of these will be used at a time
UNRESOLVED:
- Are all Klystrons and TCAVs to be made available