Search/Navigation:
Related:
SLAC/EPP
/HPS Public
Jefferson Lab/Hall B
/HPS Run Wiki
S30XL-LESA/LDMX
Table Mapping as of 111/1719/2014
GUI FEB ID | Physical FEB | Status | Comment |
---|---|---|---|
0 | L1t | OK | |
1 | L2-3t | OK | |
2 | L5t | OK | |
3 | L6t | OK | |
4 | L4t | OK | |
5 | L4b | OK | |
6 | L5b | OK | |
7 | L6b | OK | |
8 | L2-3b | OK | |
9 | L1b | OK |
GUI Flange ID | Physical Flange Board | Status |
---|---|---|
0 | 1 (top) | OK |
1 | 2 | OK |
2 | 3 | OK |
3 | 4 (bottom) | OK |
2015
L1t is now FEB 01
L4b is now FEB 15
There are no FEBs mounted for L6t or L6b.
02/01/2015
L6b is now FEB 04
L6t is now FEB 13
Low voltage:
DB44 connector | FEB # | FEB # |
---|---|---|
P1 | L1t | L2t |
P2 | L5t | L6t |
P3 | L4t | L4b |
P4 | L5b | L6b |
P5 | L1b | L2b |
High voltage:
REDEL connector | FEBs |
---|---|
1 | Top half (top connector) |
2 | Bottom half (bottom connector) |
Typically after a reboot we need to reload the pgp card driver.
$ cd /u1/pgpcard/software/driver_old/
$ ./ pgpcard_load
Start the DAQ:
$ cd /u1/software/software_new
...
Check that the hybrid currents measured are ok. Sync status for each channel can be seen in register RceCore/DataPath[x]/Synced, 1xf for powered channels.