Motor Checklist
Purpose | Base PV | Connection | pmgr | python device | Cabled? | Verified/Homed? |
---|---|---|---|---|---|---|
Standard Motors | ||||||
MXI | ||||||
MXI Hexapod | MEC:HEX:02 | Flange T3 to Hexapod 2 controller top of target chamber. | N/A | Yes | Yes | |
MXI linear stage | MEC:USR:MMS:21 | Micronix PPS-110 stage to Flange B7/H<tbd> to PR60 patch panel MEC:USR:MMS:21 connection | Crystal Y | |||
Zyla 500 mm linear stage | MEC:PPL:MMN:24 | In-air Direct cabling to XPS3, Card #8 | Newport | Yes | Yes |
Other Devices Checklist
Purpose | Base PV | Connection | Cabled? | Operational? |
---|---|---|---|---|
Permissive Signal | ||||
Trigger | MEC:USR:AIN:9 | User timing and firing unit permissive output (+5V 100 microsec pulse) to R62 EK9000, second KL3404 (card 11), first channel, PV MEC:USR:AIN:9. KL3404 specs are "4-channel analog input, voltage, ±10 V, 12 bit, single-ended" May need pulse extended, e.g. with a function generator, for detection by PLC. | Yes |
Detectors Checklist
Detector | Serial # | DAQ alias | Connection | Cabled? | In DAQ? |
---|
in-air
Power:
Fiber:
in-air
Power:
Fiber:
in-air
Power:
Fiber:
in-air
Power:
Fiber:
in-air
USB/Fiber extender to daq-mec-cam02
Alvium TBD | polarimetry_1 | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | polarimetry_2 | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | polarimetry_3 | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | polarimetry_4 | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | timetool | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | near_far | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | spot_imager | I/O:
Trigger: PR60 PP #NN | |||
Alvium TBD | electron_spec | I/O:
Trigger: PR60 PP #NN | |||
Andor Zyla | zyla | I/O:
Trigger: PR60 PP #NN |