- Ensure gun cavity tuners are in force mode
- Set force to approximately 500 N
Image RemovedImage Added
Run Initialization sequencer
...
- Turn follow PRL ‘OFF’
- Set phase rotation to 0
- Set Duty Cycle to 5%
- Set PW to 20 ms
- Set Frequency tracking ‘ON’
- Set Gain Phase tracking to ‘ON’
- Turn A&P Feedback Close Loop ‘OFF’
- Set cavity frequency to “cold” (approximately 400 kHz from nominal)
- Turn RF ‘ON’
Image RemovedImage Added
Turn RF 'On' in open loop
- Open ‘Control Loop’ screen
- Set Clip DAC at: 2500
- Set DAC to 2000
Image RemovedImage Added
Gun SSA Balancing
- Balance SSAs if reflected power is too high
- For the gun system reflected power should be less than 20 W per channel
Image RemovedImage Added
Go to nominal amplitude - iterate steps 1 - 4 according to table
- Close the Amp/Phase feedback loop
- Adjust the clip DAC setting
- Increase the amplitude in volts
- Adjust the clip DAC setting as needed
Clip DAC (counts) | Amplitude setpoint (MV) |
~ 2000 | .07 |
~10000 | .35 |
~18000 | 0.77 |
Image RemovedImage Added
Increase the duty cycle
...
Monitor the I vs. Q and assist the gain phase tracking loop if necessary.
Image RemovedImage Added
Activate the gun cavity tuners
- Drive the gun cavity toward nominal frequency by adjusting tuners in force mode
- Adjust in 50 N steps with 15 – 20 seconds per adjustment
- Stop when cavity RF frequency is within 180 Hz of nominal
- Expect the final force to be 3000-5000 N
Image RemovedImage Added
Stop tracking cavity frequency
...
If the landing frequency from the process above is not 0 Hz from the desired nominal frequency, then adjusted the drive to nominal in 180 Hz steps
Image RemovedImage Added
Lock RF to the Phase Reference Lin (PRL)
...
- Open A&P feedback loop
- Initiate following the PRL
- Close A&P feedback loop
Image RemovedImage Added
Transition to CW RF
...
The CW Power Ratio should be set to 0.005 for this transition
Image RemovedImage Added