mkdir cramfs_top
cp /afs/slac/package/rtems/4.9.1<version>/target/ssrlAppsssrlApps<lvl>/m68k-
rtems/uC5282/img/netboot.flashimg.bin cramfs_top/netboot.bin
Note: If your board is a 80MHz version of Coldfire, then you want to use netboot and rtems from 4.9.4/target/rtems_p1/ssrlApps_p3/
2 Generate cramfs image (need mkcramfs utility) on host computer
...
Note: For more recent vesions of the rtems (for example 4.9.x), one can tftp in netboot.flashimg.bin directly, without having to compress it first.
3
...
Connect to serial port
Connect serial port (Example: on BPM chassis) to serial port on your computer. (It must be a straight-through cable.) Connect to your local serial port using a terminal emulation program (Tera Term Pro on Windows works).
Note: If connecting through DIGI Terminal Port Server, connect the serial port of device/chassis containing Coldfire module, to one of the serial ports of the DIGI.
To use iocConsole program to do serial communications with the DIGI:
(a) Add your Coldfire EIOC to screeniocs file, the configuration file for iocConsole.
For development environment, this file is in /afs/slac/g/lcls/epics/ioc/iocCommon/screeniocs.
This file lets association of a DIGI Serial Port number with your <coldfire_eioc_nodename>
(b) From a development linux host, such as lcls-dev2:
> source /afs/slac/g/lcls/tools/script/ENVS.bash
> iocConsole <coldfire_eioc_nodename>
Example: iocConsole 134.79.219.81
Power up the Coldfire device/chassis (Example: BPM chassis).
4 At the uCbootloader prompt B$, set the IP address environment variable, for example:
...
B$ printenv
FACTORY=Arcturus Networks Inc.
REVISION=uC5282 Rev 1.1 16MB External Flash
SERIAL=X49E5FA37-01080
CONSOLE=ttyS0
KERNEL_ARGS=root=/dev/mtdblock0 quiet
HWADDR0=00:06:3B:00:F0:80
FW_VERSION=010808012
_0=10000000:1000000:RW
CACHE=on
KERNEL=0:netboot.flashimg.bin
BP_SRVR=134.79.19.29
BP_FILE=afsnfs2:/afs/slac:package/rtems/4.9.1/target/ssrlApps/m68k-rtems/uC5282/bin/rtems.ralf
IPADDR0=134.79.219.113
NETMASK=255.255.252.0
Note: There is a slight difference in setting up the flash partition for a 4 M Coldfire and a 16 M Coldfire:
For 4M Coldfire, the partition as above will work - so nothing needs to be set up specifically.
For 16M Coldfire, the partition must be setup as follows:
_0=10000000:100000:RW
_1=10100000:F00000:RW
Read the manual /afs/slac/package/rtems/<version>/src/ssrlApps<lvl>/netboot/README.uC5282 which explains how to deal with 16M of flash.
B$ go
uncompress... go! 0x40000
...