Longitudinal...: Brings up the Detailed Display for the 120Hz Longitudinal Feedback
Update Act Refs...: Runs a script to copy the Longitudinal RF Actuator and Offset values to storage PVs.
Restore Acts...: Runs a script restore the Longitudinal RF Actuator and Offset values from the storage PVs 
Configure...: Runs the feedback configuration applications.
Log...: TBD

Longitudinal Feedback

...

Parameters

The Desired row is a set of toggle controls that allow the operator to choose which Longitudinal Parameters the feedback should maintain. The parameters are the DL1 Energy, BC1 Energy and Peak Current, BC2 Energy and Peak Current, DL2 Energy.  By clicking on a square the operator can choose to maintain the parameter (green) or disable the feedback for that parameter (grey).

The Actual row displays the Longitudinal Parameters the feedback is currently maintaining. Sometimes this is not the same as the Desired parameters. For example, when TD11 is in the feedback cannot maintain the BC2 or DL2 parameters.