At the end of the scan, the calculated calibration parameters will be printed to the console and the X/Y scale changes will be plotted.  Please put these in the physics logbook.

...

Implementing Saved Calibration Data (INVASIVE)

  • From Cavity BPM Calibration - Main, launch the Plot/Implement Calibration Data... display.
  • Select the BPMs and planes you want to implement a calibration for by clicking individual boxes or using the Select all..., Deselect all... buttons.
  • Open the Implement calibration... display, which will prompt you to confirm by pressing the Calibrate button.

This opens matlab, prompts you to choose a saved data file, then implements the saved calibration parameters for the BPMs you have chosen.

...

Plotting Saved Data (NOT INVASIVE)

You can also plot saved calibration data.

  • From Cavity BPM Calibration - Main, launch the Plot/Implement Calibration Data... display.
  • Press the Load File and Plot Data button.

This opens matlab, prompts you to choose a saved data file, then plots the calibration data from that file.

...

Plotting Summary of Saved Data (NOT INVASIVE)

You can also plot just the X and Y scaling factor changes.

  • From Cavity BPM Calibration - Main, launch the Plot/Implement Calibration Data... display.
  • Press the Load File and Plot Summary button.

This opens matlab, prompts you to choose a saved data file, prints a list of results and plots the X and Y scaling factor changes.

...