Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This page collects information about a total absorption dual readout calorimeter as implemented in SLIC. You will find information about the detector parameters, how to run the simulation, where data sets and programs to analyze the data can be found.  The dual read out/ optical processes group meets every Tuesday at 10 9 am in the Quarium wh 8th floor. It is possible to dial in by phone or follow the meeting via skype. The agenda page can be found on the following web page:
http://ilcagenda.linearcollider.org/categoryDisplay.py?categId=151

...

Material

Density

Radiation length

Interaction length

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="8a4f30d3305f080f-12903aa9-44894ed8-bda99cd1-21a0825946cd7191a70fc21a"><ac:plain-text-body><![CDATA[

 

[g/cm3]

[cm]

[cm]

]]></ac:plain-text-body></ac:structured-macro>

BGO

7.13

1.12

21.88

PbWO4

8.3

0.9

18.

SCG1-C

3.36

4.25

45.6

...

 

 

 

 

BGO

 

PbWO4

 

Detector

Layers

Thickness/layer

Segmentation

X0

Lambda

X0

Lambda

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="051626c228ee3071-73fcb14a-43ea482d-b54b8ceb-3dae764e53c5935d2bae3817"><ac:plain-text-body><![CDATA[

 

 

[cm]

[cmxcm]

 

 

 

 

]]></ac:plain-text-body></ac:structured-macro>

ECAL Barrel

8

3

3x3

21.4

1.1

27

1.3

HCAL Barrel

17

6

6x6

 

4.7

 

5.7

Total Barrel

25

 

 

 

5.8

 

7

 

 

 

 

 

 

 

 

ECAL EndCAP

8

3

3x3

21.4

1.1

27

1.3

HCAL EndCAP

17

6

6x6

 

4.7

 

5.7

Total EndCAP

25

 

 

 

5.8

 

7

...