This page collects information about a total absorption dual readout calorimeter as implemented in SLIC. You will find information about the detector parameters, how to run the simulation, where data sets and programs to analyze the data can be found. The dual read out/ optical processes group meets every Tuesday at 10 9 am in the Quarium wh 8th floor. It is possible to dial in by phone or follow the meeting via skype. The agenda page can be found on the following web page:
http://ilcagenda.linearcollider.org/categoryDisplay.py?categId=151
...
Material | Density | Radiation length | Interaction length | ||
---|---|---|---|---|---|
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="8a4f30d3305f080f-12903aa9-44894ed8-bda99cd1-21a0825946cd7191a70fc21a"><ac:plain-text-body><![CDATA[ |
| [g/cm3] | [cm] | [cm] | ]]></ac:plain-text-body></ac:structured-macro> |
BGO | 7.13 | 1.12 | 21.88 | ||
PbWO4 | 8.3 | 0.9 | 18. | ||
SCG1-C | 3.36 | 4.25 | 45.6 |
...
|
|
|
| BGO |
| PbWO4 |
| ||
---|---|---|---|---|---|---|---|---|---|
Detector | Layers | Thickness/layer | Segmentation | X0 | Lambda | X0 | Lambda | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="051626c228ee3071-73fcb14a-43ea482d-b54b8ceb-3dae764e53c5935d2bae3817"><ac:plain-text-body><![CDATA[ |
|
| [cm] | [cmxcm] |
|
|
|
| ]]></ac:plain-text-body></ac:structured-macro> |
ECAL Barrel | 8 | 3 | 3x3 | 21.4 | 1.1 | 27 | 1.3 | ||
HCAL Barrel | 17 | 6 | 6x6 |
| 4.7 |
| 5.7 | ||
Total Barrel | 25 |
|
|
| 5.8 |
| 7 | ||
|
|
|
|
|
|
|
| ||
ECAL EndCAP | 8 | 3 | 3x3 | 21.4 | 1.1 | 27 | 1.3 | ||
HCAL EndCAP | 17 | 6 | 6x6 |
| 4.7 |
| 5.7 | ||
Total EndCAP | 25 |
|
|
| 5.8 |
| 7 |
...