Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Multipacting simulation on beampipe step shows there are several MP barriers, the hardest is at 29.4 MV/m. Based on our simulation results and KEK?s measurement data, Saito construct below table which shows our simulation agree very well with their measurement, both have same MP barriers.

MP simulation on TTFIII coupler

coax

bellow

step region

ceremic window

...