There are three periods of test beams in which 3D sensors will be tested at CERN. This page contains a placeholder for notes/reminders for preparation.

MCC board

This is described Description of the board and how to operate it here: MCC boards at SLAC.

  • Modification of the Oslo reconstruction code Ole
  • Modify the BAT online monitoring Pelle,BAT

...

  • expert
  • Implement the ATLAS module/MCC in the EUDET framework Georg
  • Implement online monitoring capabilities (minimum is correlation plots) for each channel in EUDET framework Georg
  • Tests to be done at CERN
    • Run source scan with >1 chip, moving the source over the chips to see hits in all attached chips for same source scan Pelle & Alessandro
    • Run with BAT software to check monitoring

EUDET Telescope

  • Hardware modifications on TPLL Jens
    • TPLL boards from Oslo and Manchester are modified, already sent? Ole,Cinzia
  • Mount for devices ?
    • How many devices can fit in the telescope
    List of tests to be carried out before using (Pelle & Alessandro)

10-17 October

DUT's
  • List of devices under test
    • STA-3D (2E,3E and 4E?)
      • Check if the 2E and 4E can be revived Pelle, Alessandro
    • CNM
    • SINTEF
    • FBK (irradiated?)

...

EUDET Telescope

...

  • Hardware modifications on TPLL
    • TPLL boards from Oslo and Manchester are modified
    • If we use the MCC board only one (with some backup perhaps) needs to be modified
  • Software changes
    • Minor modification for the Oslo reconstruction code (Ole)
    • Need to modify the BAT online monitoring if we use the MCC board.
    Mount for devices
    • How many devices can fit in the telescope
Run plan

Should focus on measurements that require the extra resolutions

...

  • List of devices under test
    • STA-3D (2E,3E and 4E?)
    • CNM
    • SINTEF
    • FBK (irradiated?)
  • Mounting (using BAT either in H6 or H8) ?
    • Prefered choice: Use the cooling box prepared for EUDET TB period (above), needed if we test irradiated sensors
    • Backup choice is to use box from May even if there is no required cooling
    • If irradiated sensors are used then we need to verify the cooling in the box (Anyone?)
    • The May cooling box could hold only 4 DUTs, using MCC it is easy feasable to test at least 8 Need new box/mountingNO? required cooling
Run plan

Should focus on the measurements to validate the 3D performance and fill in the information we are lacking from the May TB.

...