Is an implementation of a daul read-out, total absorption crystal calorimeter made of BGO crystals. CCAL02 is based on the SID02 geometry but the space currently occupied by ECAL/HCAL Barrel/Endcap is replaced by the Crystal calorimeter. All other detectors (tracking etc.) as they are. ECAL deep enough to contain most EM showers.
The following table lists the properties of some crystal materials.
Material | Density | Radiation length | Interaction length | ||
---|---|---|---|---|---|
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e7d9ff328f577a9e-a17c4294-40984278-83a3936c-e4c6b1e02d13ea22b63e731d"><ac:plain-text-body><![CDATA[ |
| [g/cm3] | [cm] | [cm] | ]]></ac:plain-text-body></ac:structured-macro> |
BGO | 7.13 | 1.12 | 21.88 | ||
PbWO4 | 8.3 | 0.9 | 18. | ||
SCG1-C | 3.36 | 4.25 | 45.6 |
The following table lists the parameters of the ccal02 calorimeter:
|
|
|
| BGO |
| PbWO4 |
| ||
---|---|---|---|---|---|---|---|---|---|
Detector | Layers | Thickness/layer | Segmentation | X0 | Lambda | X0 | Lambda | ||
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e78dec15b8335c4f-1a1635e2-47064f06-a9eab7c0-48b5ed5d895b837bfe4dbdd8"><ac:plain-text-body><![CDATA[ |
|
| [cm] | [cmxcm] |
|
|
|
| ]]></ac:plain-text-body></ac:structured-macro> |
ECAL Barrel | 8 | 3 | 3x3 | 21.4 | 1.1 | 27 | 1.3 | ||
HCAL Barrel | 17 | 6 | 6x6 |
| 4.7 |
| 5.7 | ||
Total Barrel | 25 |
|
|
| 5.8 |
| 7 | ||
|
|
|
|
|
|
|
| ||
ECAL EndCAP | 8 | 3 | 3x3 | 21.4 | 1.1 | 27 | 1.3 | ||
HCAL EndCAP | 17 | 6 | 6x6 |
| 4.7 |
| 5.7 | ||
Total EndCAP | 25 |
|
|
| 5.8 |
| 7 |
...