Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Is an implementation of  a daul read-out, total absorption crystal calorimeter made of BGO crystals. CCAL02 is based on the SID02 geometry but the space currently occupied by ECAL/HCAL Barrel/Endcap is replaced by the Crystal calorimeter. All other detectors (tracking etc.) as they are. ECAL deep enough to contain most EM showers.
The following table lists the properties of some crystal materials.

Material

Density

Radiation length

Interaction length

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e7d9ff328f577a9e-a17c4294-40984278-83a3936c-e4c6b1e02d13ea22b63e731d"><ac:plain-text-body><![CDATA[

 

[g/cm3]

[cm]

[cm]

]]></ac:plain-text-body></ac:structured-macro>

BGO

7.13

1.12

21.88

PbWO4

8.3

0.9

18.

SCG1-C

3.36

4.25

45.6

The following table lists the parameters of the ccal02 calorimeter:

 

 

 

 

BGO

 

PbWO4

 

Detector

Layers

Thickness/layer

Segmentation

X0

Lambda

X0

Lambda

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="e78dec15b8335c4f-1a1635e2-47064f06-a9eab7c0-48b5ed5d895b837bfe4dbdd8"><ac:plain-text-body><![CDATA[

 

 

[cm]

[cmxcm]

 

 

 

 

]]></ac:plain-text-body></ac:structured-macro>

ECAL Barrel

8

3

3x3

21.4

1.1

27

1.3

HCAL Barrel

17

6

6x6

 

4.7

 

5.7

Total Barrel

25

 

 

 

5.8

 

7

 

 

 

 

 

 

 

 

ECAL EndCAP

8

3

3x3

21.4

1.1

27

1.3

HCAL EndCAP

17

6

6x6

 

4.7

 

5.7

Total EndCAP

25

 

 

 

5.8

 

7

...