Introduction

This page collects information about a total absorption dual readout calorimeter as implemented in SLIC. You will find information about the detector parameters, how to run the simulation, where data sets and programs to analyze the data can be found. 

Principle of a dual read out calorimeter

...

Material

Density

Radiation length

Interaction length

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="2be83fa9022058d5-e5be6069-44cf42b6-b66a81a7-9f018f5fc4a502cbacdfc5db"><ac:plain-text-body><![CDATA[

 

[g/cm3]

[cm]

[cm]

]]></ac:plain-text-body></ac:structured-macro>

BGO

7.13

1.12

21.88

PbWO4

8.3

0.9

18.

SCG1-C

3.36

4.25

45.6

 

 

 

 

BGO

 

PbWO4

 

Detector

Layers

Thickness/layer

Segmentation

X0

Lambda

X0

Lambda

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="d96445f90dd84abd-993e9260-45844125-b899bf48-225cb5aadeb8511e7a1562fe"><ac:plain-text-body><![CDATA[

 

 

[cm]

[cmxcm]

 

 

 

 

]]></ac:plain-text-body></ac:structured-macro>

ECAL Barrel

8

3

3x3

21.4

1.1

27

1.3

HCAL Barrel

17

6

6x6

 

4.7

 

5.7

Total Barrel

25

 

 

 

5.8

 

7

 

 

 

 

 

 

 

 

ECAL EndCAP

8

3

3x3

21.4

1.1

27

1.3

HCAL EndCAP

17

6

6x6

 

4.7

 

5.7

Total EndCAP

25

 

 

 

5.8

 

7

How to run the simulation

Available Data sets

The Table below list all the data samples currently available at Fermilab. The files can be found on the following directory (on the bluearc system)

...