Correlation between the total observed ionization energy and the electromagnetic component of the shower, as measured by the Cherenkov component. The calibration factor K is determined by the requirement that K×ECherenkov = Eionization for electrons.
The CCAL02 detector
Is an implementation of a daul read-out, total absorption crystal calorimeter made of BGO crystals. CCAL02 is based on the SID02 geometry but the space currently occupied by ECAL/HCAL Barrel/Endcap is replaced by the Crystal calorimeter. All other detectors (tracking etc.) as they are. ECAL deep enough to contain most EM showers.
Material | Density | Radiation length | Interaction length | ||
---|---|---|---|---|---|
<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="3e6449a5f186f4fc-22ed00ad-41ea47fc-a1b283f7-f45a322baa2f702fde7ece50"><ac:plain-text-body><![CDATA[ |
| [g/cm3] | [cm] | [cm] | ]]></ac:plain-text-body></ac:structured-macro> |
BGO | 7.13 | 1.12 | 21.88 | ||
PbWO4 | 8.3 | 0.9 | 18. | ||
SCG1-C | 3.36 | 4.25 | 45.6 |