Correlation between the total observed ionization energy and the electromagnetic component of the shower, as measured by the Cherenkov component. The calibration factor K is determined by the requirement that K×ECherenkov = Eionization for electrons. 

The CCAL02 detector

Is an implementation of  a daul read-out, total absorption crystal calorimeter made of BGO crystals. CCAL02 is based on the SID02 geometry but the space currently occupied by ECAL/HCAL Barrel/Endcap is replaced by the Crystal calorimeter. All other detectors (tracking etc.) as they are. ECAL deep enough to contain most EM showers.

Material

Density

Radiation length

Interaction length

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="3e6449a5f186f4fc-22ed00ad-41ea47fc-a1b283f7-f45a322baa2f702fde7ece50"><ac:plain-text-body><![CDATA[

 

[g/cm3]

[cm]

[cm]

]]></ac:plain-text-body></ac:structured-macro>

BGO

7.13

1.12

21.88

PbWO4

8.3

0.9

18.

SCG1-C

3.36

4.25

45.6