Details (release notes for dataMonitoring/AlarmCfg for v5r18p)
v5r18p2
A few more alarms protected against low statistics.
- Digi eor:
- CondArrCNO_CalLoOpensWindow_TH1: added condition on min entries (1000) for algorithms x_average, x_rms and low_high_ratio, reference_histogram.
- CondArrTKR_CalLoOpensWindow_TH1: added condition on min entries (20000) for reference histogram.
- FastMon eor:
- CondArrCNO_CalLoOpensWindow_TH1: added condition on min entries (1000) for algorithms x_average, x_rms and low_high_ratio, reference_histogram.
- CondArrTKR_CalLoOpensWindow_TH1: added condition on min entries (20000) forreference histogram.
v5r18p1
A few more alarms protected against low statistics.
...