Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

September 18th: Matthew and Elizabeth

SAS 0 --> 6
  --> Two lanes make to DPM. Rerouted through breakout board.
SAS 1 --> 7
  --> All four lanes make to DPM
SAS 2 --> 8
  --> All four lanes make to DPM

Testing PPOD functionality:

PPODSAS 0SAS 1SAS 2
AE100851OKOKOK
AE100856OKOKOK
AE100849OKOKOK
AE100846OKOKOK
AE100827OKOKOK

CtrlDPM died after tests to AE100849 were completed. The problematic DPM (dpm3) was switched out using another available board. Old dpm3 is now dpm1, new CtrlDPM is dpm5.


September 20th:

Testing Flange Boards:

Flange BoardSAS 0SAS 1SAS 2Flange Board Current (A)PPOD
Flange0No slow control.No slow control.No slow control.0.373AE100856
Flange1OKOK (took two tries)OK0.525AE100846
Flange2OKOKOK0.525AE100849
Flange3OKOKOK0.521AE100851

Numbering convention is top (0) to bottom (3).

Noticed QSFP housing on Flange0 was a bit tilted, back pins were loose. After adjusting the board a bit and re-powering, were able to see all hybrids. Observed flange current flickering between ~0.2 and 0.4 A on first power-up. 


Looking for error bits during prolonged running: 

Flange Board

SAS 0

Errors/Frames

SAS 1

Errors/Frames

SAS2

Errors/Frames

Flange Board Current (A)PPOD
Flange0



AE100856
Flange1

No errors

Frames: 960

DPM1, Link1:

RxFrameErrorCount=1

RxCellErrorCount = 1

No error messages.

Frames: 1000

No errors

Frames: 1050 (17 min)

0.525AE100846
Flange2

No errors

Frames: 970

No errors

Frames: 1000

DPM1,Link0:

RxFrameErrorCount=2

RxCellErrorCount=2

Error messages: PollQueue checkTransaction error

Frames: 1100

0.525AE100849
Flange3

No errors

Frames: 950

No errors

Frames: 1000

FEB link dropped after ~10 min of running, FEB current down to 1.072 from 1.24 A.

No errors, even after FEB lost (?).

Frames: 650

0.521AE100851