PurposeBase PVConnectionpmgrpython deviceCabled?Verified/Homed?
Standard Motors
MXI

JJ Slits

Not in questionnaire

4 motors

JJ Slits

MEC:TC1:MMS:[17,18]

MEC:TC1:MMS:[01,02]

T5/2 and T5/8

...

MXI HexapodMEC:HEX:02Flange T3 to Hexapod 2 controller top of target chamber.N/A
YesYes
MXI linear stageMEC:USR:MMS:21Flange B7/H<tbd> to PR60 patch panel MEC:USR:MMS:21 connectionCrystal Y


Detectors Checklist 

DetectorDAQ aliasConnectionCabled?In DAQ?
epix10k-540kquad_0
  • Power: Quad 0 vac cable -> Flange B3, Q0 feedthru -> air cable "epix10k quad 0" -> MPOD quad outlet 0
    • Note: vac cable labeled "PDU Cable Epix10k Q0" on quad side but "epix10k quad2" on flange side.
  • Fiber: using "epix10k quad 0" vacuum and air fibers. Flange B2, feedthru pair 0 -> PR60 patch panel quad port 0

    in-air

    Power:

    Fiber: 



    epix10k-540kquad_1

    in-air

    Power:

      TBD -> Flange B3, Q2 feedthru -> air cable "epix10k quad 2" -> MPOD quad outlet 1

    Fiber:

    using "epix10k quad 21 vacuum and air fibers. Flange B2, feedthru pair 2 -> PR60 patch panel quad port 2
  • Note on vacuum power cables:
    • Using cable "PDU Cable epix10k Q1": Minor alarm on DVDD when ON, HV error when failed to configure in the DAQ.
    • There is a second cable from Phil "epix10k quad 0" that I have not tested. It is on the optical table.
  • epix10k-540kquad_3
    • Power:  Quad 3 vac cable -> Flange B3, Q3 feedthru -> air cable "C01 April 2024" -> MPOD quad outlet 3
    • Fiber: using "epix10k quad 3" vacuum and air fibers. Flange B2, feedthru pair 3 -> PR60 patch panel quad port 3

    ePix100

    SW Epix100a

    "epix100a_f"

    • Power: Flange B3, South feedthru -> power cable E1 -> MPOD outlet 1
    • Fiber: using "epix100a epix 1" vacuum and air fibers. Flange D2 (left) -> PR60 patch panel epix port 1 → MTP to daq-mec-cam01
    • MECHome: "Epix 1"
    • DAQ: "epix100a_1_bxrts"

    ePix100

    NE Epix100a

    "epix100a_b"

    • Power: Flange B3, North feedthru -> power cable E0 -> MPOD outlet 2
    • Fiber: using "epix100a epix 0" vacuum and air fibers. Flange D2 (upper) -> PR60 patch panel epix port 2 → MTP to daq-mec-cam01
    • MECHome: "Epix 2"
    • DAQ: "epix100a_2_fxrts"

     



    epix10k-549kquad_2

    in-air

    Power:

    Fiber: 



    epix10k-540kquad_3

    in-air

    Power:

    Fiber: 



    Andor Zylazyla

    in-air

    USB/Fiber extender to daq-mec-cam02

    XRT spectrometerhxsssN/AN/A