  • Formatting was changed.

...

This new GR, v15r47p7, uses the new LDF v7-01-01 which correctly deals with the TEM bug and phasing error events. In particular, it will no longer try to parse obviously corrupted (out of synch) information. An added benefit is that the digitization log files will no longer be filled with hundreds of thousands of lines of messages from the parsing of this corrupt information (complaining about unphysical strip hits etc). All this junk output would drown out any important messages. Note that events with the TEM bug or phasing errors are not reconstructed. This does not change. So this only affect data in the the digi files. For the better.

We also have a few bug fixes and updates for the monitoring (among other things checking each FT2 file to see if the livetime in a 30-second period is negative or larger than 30 seconds) and the addition of a new variable in the SVAC ntuple (signaling the presence of a TEM bug).

Test Procedure

We have processed data runs in the DEV pipeline with this version of L1Proc.

...

We can switch back to the previous version of L1Proc.

CCB Jira

SSC-182@JIRA189@JIRA

Details

L1Pipeline v1r72:
-

...

svac/TestReport: v9r0
- Added verify module for ft2 files (LONE-137)
- Fixed a bug in the tuncation from command line
- Truncation is now done per-error and not per-event

...