Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

A number of the data lanes from the ASICs are intermittent on the device we're testing with (0016778240-0000000000-0000000000-4032267777-3204448280-0177427457-3053453334).  After disabling these lanes, the current detector interface provides images in AMI like the first image below.  After Dawood adjusted various App.SspMonGrp[*].UsrDlyCfg[*] values, more lanes became reliable (second image).  This configuration was tested with Run/DAQ triggers set to 100/100, 5000/100, 5000/5000, 5000/2500, and 4000/2000 Hz.

Image Added

As of April 1, 2024, another detector (0016778240-0176075265-0452984854-4021594881-1962934296-0177446913-0402653206) is being readied for an upcoming beam test.  With the delays provided by the detector-specific .yml file and the automatic bad lane disablment done by the Root class on Configure, the third image above was and (later) fourth images above were obtained.

Running the DAQ

To run the DAQ with the ePixM, a recent (to April 2, 2024) version of the build is necessary.  The following needs to be done only when a new release must be installed.

...