How to get magnet values from S20 Config tool and the SpecLine GUI:

From the S20 Config (from facethome, Physics Apps) - calculate the match values for each step:

  1. Select the IP waist location (or reference position) under the "IP Primary Wiast Location"
  2. Enter the desired beta function under "Beta Functions at IP Location"
  3. Set the location to image the beam to in the spectrometer under "Downstream IP Match Conditions". Note - you can ignore this if you are setting fixed spectrometer values separately SpecLine GUI.
  4. Click "Do Match"
  5. Enter the waist offset DES value (this is the offset from the selected IP waist location)
  6. Click "waist→DES"
  7. Record the values from the "Match" line. (Do not use the BDES values)
  8. Enter a new waist offset, click "Waist→DES", record
  9. Repeat for all steps


To set the spectrometer quads - use the SpecLine GUI (From LI20 Profile Monitors)

  1. Enter the desired "Spectrometer Parameters"
  2. Click "Calculate"
  3. Record the values from the BCALC column for the values for: Q0D Q1D Q2D