Objective
The main objective of this project is to be able to use subsystems built for the LCLS-I reference frequencies with the LCLS-II beam. The beneficiaries include XTCAV, STCAV and possibly others. In order to do that, the 476MHz Master Oscillator (MO) signal for LCLS-I should be replaced with a new 476MHz source locked to the LCLS-II Master Oscillator (, with the latter operating at 162.5MHz).
Requirements
The requirements for this project are listed below.
- Generate a 476MHz RF reference in Sector-2 for to use with XTCAV. The RF reference will have similar jitter characteristics as the LCLS-II Master Oscillator.
- Transmit a 476MHz RF reference to Sector-10 to replace the LCLS-I Master Oscillator. The new RF reference will have similar jitter characteristics as the existing LCLS-I Master Oscillator.
- Align the triggerring of the Super-Conducting (SC) & Normal-Conducting (NC) timing systems for XTCAV to operate at 120Hz.
- Merge the NC event timing on onto the SC event timing.
Timing System Description
...