  • Cryotel IOC (Patrick's update)
    • IOC screen has PID controls, but since we only use PID in archon, that section will be wiped before we give this to users
    • For cryotel screen:
      • Hit only POWER mode: constant cooling, 60W
      • ON mode aka temperature mode: uses PID to get there
    • 3/8" tubing for chiller, raise flow rate
    • Software wise, everything is in place (trigger from the archon, timing, etc)
    • RIX:STA:CCD:01 as the base name for the PVs
  • Waiting to hear from Dan about archon IOC and testing sensor in RIXS daq
  • Next steps: meet with Dan, test basic functions, do a full cool-down/data collection/warmup at RIXS



This is a how-to for a single sensor. Ultimately, there will be two of these sensors at qRIXS. 

...