- Open Long pulse laser operation from MEC home
- Open Lecroy B A scope to monitor 10Hz pulse shape
...
- If trace is not present on Lecroy BA, make sure that 10Hz operation is enabled.
- If the trace is not present, confirm shutter 4 on the LSS is on
- If the trace is still not present, it may be necessary to cycle meclas.YFE.Off() and meclas.YFE.On() until the trace is present.
...
Figure 5: choose the pulse recipe: use commend "meclas.LPL.psmenu()" Figure 6: shape the 10Hz pulse as designed.
Note: If meclas.LPL.psefc10Hz() is run, then the default number of iterations is set at 50. Running this command consecutively three times will provide the same results as meclas.LPL.psefc10Hz(numIterQ=150).
- It may be necessary to repeat meclas.LPL.psefc10Hz(numIterQ=150) if the blue trace is not fit well to the red trace.
...