- Close the Amp/Phase feedback loop
- Adjust the clip DAC setting
- Increase the amplitude in volts
- Adjust the clip DAC setting as needed
Clip DAC (counts) | Amplitude setpoint (MV) |
~2500 | 0.02 |
~6500 | 0.05 |
~10500 | 0.08 |
~17500 | 0.135 |
Increase the duty cycle up to 99.85%
...
- Open A&P feedback loop
- Initiate following the PRL
- Close A&P feedback loop
Transition to CW RF
1.Ramp to 99.99% duty cycle
2.When at 99.99% duty cycle, transition to CW is accomplished with a single sequenced button: “To CW”1.
...
- Set amplitude to 0.8% lower than the current setpoint
The CW Power Ratio should be set to 0.008 for this transition
Image Added