6. Toggle this back to "Disabled" to stop pulsing.

How to shut down after gas jet operation or get into safe state to move the gas jet assembly

  1. Close Fill valve
  2. Check the Picnic Basket (EPS) valve is Open
  3. Check the scroll pump at pen 20-12 is running and there are no manual valves closed...
  4. Open drain valve
  5. Wait a moment for the line to evacuate. Now it will be safe to move the gas jet assembly.
  6. Close the drain valve
  7. If you are completely shutting down for the end of the experiment, close the Picnic Basket (EPS) valve
  8. Close gas bottle valve

...