How to change rep rate or pulse duration

...

Info

This assumed Iota controller is set to external triggers and one-shot else this does nothing

...

.

  1. Go to the EVR panel: Go to facethome and LI20-Experimenter. From there, select the Triggers button (the screen shows items grouped by racks- these electronics are located in rack FKG20-24).

...

6. Toggle this back to "Disabled" to stop pulsing.

...

How to shut down after gas jet operation

...

  1. Close Fill valve
  2. Check the scroll pump at pen 20-12 is running and there are no manual valves closed...
  3. Open drain valve
  4. Close gas bottle valve


Info
Any issues with the shutdown please contact Christine right away. It's important that we "de-energize" the system and pump out the gas if this is left unattended.