Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: New waveform-related signals for discussion. Needs work...

...

NameDescription
GDESOperation Gradient setpoint (MV/m)
GACTMeasured gradient from cavity probe (MV/m)
GMAX

Maximum allowable gradient (MV/m)

GCALGradient calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output.
ADESOperation Amplitude setpoint (MV)
AACTMeasured amplitude from cavity probe (MV)
AMAX

Maximum allowable amplitude (MV)

ACALAmplitude calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output.
PDESOperation Phase setpoint (degrees, where 0 is on-crest)
PACTMeasured phase from cavity probe (degrees)
PREFa.k.a.gold, phase offset used by LLRF to convert measured phase to one relative to on-crest operation, adjusted by beam phasing (detrees)
FDESCavity detuning setpoint (Hz)
FACTDetune seen by the resonance system (Hz)
ModeRF mode (off, pulsed, SEL, GDR)
RFCTRLMaster enable for an RF cavity (On, Off) \[How to distinguish this from the SSA specific RF enable register?]
RFReadyStatus of RF controls, (Ready, Not Ready) set to ready when control loops are closed and RF is continuous. Or will we ever run with pulsed RF?
QuenchStatus showing when a cavity quenches, from interlocks (Normal, Quenched)
STATStatus bits in software (define the bits)
HSTAHardware status
GTRACEGradient waveform from the cavity probe, which is used to calculate GACT (MV/m)
PTRACEPhase waveform from the cavity probe, which is used to calculate PACT (degrees)
GFWDTRACEGradient waveform from SSA output (MV/m)
PFWDTRACEPhase waveform from SSA output (degrees)
GREVTRACEReverse/reflected SSA output gradient waveform (MV/m) I'm favoring rev over ref because ref sounds to me like "reference"
PREVTRACEReverse/reflected SSA output phase waveform (degrees)
*ERRTRACEError waveforms corresponding to waveforms above, captured and put in a separate buffer when a fault is detected (degrees or MV/m)
 Any of the above in I/Q equivalent of Amplitude/Phase
PwrFwdForward power from SSA to cavity
PwrRevReflected/reverse power from cavity
PzWFWaveforms from tuner piezo motors, useful for finding microphonics. Units TBD.
ALEMLEM computed integrated RF amplitude (MV) per cavity and per cryomodule
PLEMLEM computed phase (deg)
EGLEMLEM computed energy gain (MeV)
CHLEMLEM computed chirp (MeV)
  Below are signals to discuss added 1/17/2018 Sonya.
 GTRACE_I Gradient waveform from the cavity probe, real part
 GTRACE_Q Gradient waveform from the cavity probe, imaginary part
 GTRACE Gradient waveform from the cavity probe, amplitude. (GTRACE above)
 PTRACE Gradient waveform from the cavity probe, phase. (PTRACE above)
 GTRACE_MEAN Or GMEAN? Mean of GTRACE (may be fed into GACT?)
 PTRACE_MEAN Or PMEAN? Mean of PTRACE (may be fed into PACT?)
 GTRACE_STD Or GSTD? Standard deviation of GTRACE
 PTRACE_STD Or PSTD? Standard deviation of PTRACE
 GTRACE_MIN Or GMIN? Minimum value of GTRACE
 PTRACE_MIN Or PMIN? Minimum value of PTRACE
 GTRACE_MAX Or GMAX? Maximum value of GTRACE
 PTRACE_MAX Or PMAX? Maximum value of PTRACE
 DTRACE_I Drive; waveform of RFS chassis drive loopback, real part
 DTRACE_Q Drive; waveform of RFS chassis drive loopback, imaginary part
 DTRACE_AMPL Drive; waveform of RFS chassis drive loopback, amplitude
 DTRACE_PHAS Drive; waveform of RFS chassis drive loopback, phase
 DTRACE_AMPL_MEAN Or DAMPLMEAN? Mean of DTRACE_AMPL
 DTRACE_PHAS_MEAN Or DPHASMEAN? Mean of DTRACE_PHAS
 DTRACE_AMPL_STD Or DAMPLSTD? Standard deviation of DTRACE_AMPL
 DTRACE_PHAS_STD Or DPHASSTD? Standard deviation of DTRACE_PHAS
 DTRACE_AMPL_MIN Or DAMPLMIN? Minimum value of DTRACE_AMPL
 DTRACE_PHAS_MIN Or DPHASMIN? Minimum value of DTRACE_PHAS
 DTRACE_AMPL_MAX Or DAMPLMAX? Maximum value of DTRACE_AMPL
 DTRACE_PHAS_MAX Or DPHASMAX? Maximum value of DTRACE_PHAS
 FWDTRACE_I 
 REVTRACE_I Or REFLTRACE_I
  

 

Deployment and calibration attributes

...