Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
  • Log into the host machine and start up an RCE GUI...at CERN:
    • the host machine is:  pddaq-gen02-ctrl0
    • the software lives at: /daq/rce/software.pd/protoDUNE
    • start the gui with:  /daq/rce/software.pd/protoDUNE/rceScripts/rce_talk CERN-100 start_gui
  • From the GUI, hit the HardReset button...this sets everything to a known state
    Image Added

  • Go to the configuration tab, and set the following values: 
    • DataDpmEmu>EnableTx>True
    • DataDpmHlsMon>0x1 (or 0x2)
    • DataDpmTiming>SwFlush>False
    • DataDpmWib>RxPolarity>True
    • If you want to run in emulation mode (e.g. if you don't have a WIB hooked up), also set:
      • DataDpmEmu>Loopback>True
  • Hit the "Write Configuration" button: 
    Image Added
  • That's it...you should be receiving data to the DataBuffer...you can tell by going to the "Status" tab...should look something like this:

    Image Added

 

 

Contact

JJ Russell

russell@slac.stanford.edu