Page History
...
Completely implemented applications under calibman
tabs:
- Dark
- ROI - mask conversion will be available since ana-0.13.14
- File Manager
- Single File Manager
- Group File Manager
- Configuration - new list of queues will be available since ana-0.13.14
- Geometry
- Metrology - implemented for CSPAD CXI-V1, XPP-V2, CSPAD2x2
- Alignment - will be available since ana-0.14.01
calibrun
- command-line application is fully functional
Recommended updates
...
On 2015-04-08:wait for 15: ana-current (a.k.a. ana-0.14.01) does not need in updates.
How to get and run calibman
...
Code Block |
---|
cd <your-favorite-test-directory>; newrel ana-current testrel-CalibManagercalibmanager; cd testrel-CalibManagercalibmanager; sit_setup <release-tag>; addpkg CalibManager HEAD; addpkg <package2> HEAD; addpkg <package3> HEAD; ... scons; calibman; |
...
Available since release ana-0.10.16 (CalibManager V00-00-40
)16.
Command line interface for dark-run calibration of detectors is implemented by P.O.C.s request. It can be started by the command calibrun
with parameters. The list of parameters can be dumped on terminal by the command:
...
How to run on ffb data
Command calibrun
can work on ffb
data . In this case command using option "-x <path-to-xtc>
" needs to be specified. This option sets non-standard path to xtc files. For example:
Code Block |
---|
calibrun <options> -x /reg/d/ffb/cxi/cxi12345/xtc <more-options> |
References
Overview
Content Tools