New GUI to check hybrid sync status is now active:  svtHybSync.adl. 
It now contains information about the sync status for the FEBs. It looks like it’s working: I can see that the powered FEB right now has sync 0x0 for all data paths. The other don’t have a “valid xml” which make sense. We can change the error codes later. Please look at this and tell me if this status corresponds to what your expect. Below the sync I have information about the data DPM’s. It will allow us to see the status and configuration of all DPM’s. I’m also adding the link errors to this GUI. It works but I have turned it off now as it’s too slow. I’ll be working on that tomorrow morning. (Pelle)

2015-02-23

Updated to SVT DAQ epics. Check out instruction on  EPICS Instructions. We are now running 14 data dpm , 1 control dpm and 2 dtm control IOCs in parallel.
Added FebNum/HybNum and run state monitoring in "svtHybSync.adl" GUI from data dpm to check mapping.