- the data will be saved in the direcotry:/home/glast/DAQ-v3.00/CAENVMETest/data in ROOT format and in binary format
Acquisiton run synchronized with the CU (for tagged photons)
- working direcotory: /home/glast/DAQ-v3.00/CAENVMETest
- CHANGE THE STROBE DELAY TO 500us (move the Strobe delay knob on 1ms pos.)
- on the console write: ACQmain
- insert when reqeusted the number of events
- on the "Button Canvas" press the button:"Open Canvas"
- on the "Button Canvas" press the button."Start ACQ"
- on the console insert a brief comment to the run
- wait a Client from RunControl ("Starting server socket on port 2345 -> waiting for a client...")
- on the console you will be prompted with: "Press enter when RC is ready"
- when RunCOntrol is on PASSED status and the sweep event has been acquired you can press "enter" to start the syncronized acqusition
- when the run is enden press on the "Button Canvas" the button: "Stop"
- if tou want to abort the run press "Ctrl-c" on the keyboard. (all the data excpet the last spill will be saved anyway)
- the data will be saved in the direcotry:/home/glast/DAQ-v3.00/CAENVMETest/data in ROOT format and in binary format.
- the data will be onlime merged with the CU data.
Acquisiton run synchronized with the CU withou SSDs detecotrs (for full breemstrahlung)
- working direcotory: /home/glast/DAQ-v3.00/CAENVMETest
- CHANGE THE STROBE DELAY FROM 500us to TO 50us (move the Strobe delay knob one position anti-clokwiseon 100us pos.)
- on the console write: ACQNOSSDmain
- insert when reqeusted the number of events
- on the "Button Canvas" press the button:"Open Canvas"
- on the "Button Canvas" press the button."Start ACQ"
- on the console insert a brief comment to the run
- wait a Client from RunControl ("Starting server socket on port 2345 -> waiting for a client...")
- on the console you will be prompted with: "Press enter when RC is ready"
- when RunCOntrol is on PASSED status and the sweep event has been acquired you can press "enter" to start the syncronized acqusition
- when the run is enden press on the "Button Canvas" the button: "Stop"
- if tou want to abort the run press "Ctrl-c" on the keyboard. (all the data excpet the last spill will be saved anyway)
- the data will be saved in the direcotry:/home/glast/DAQ-v3.00/CAENVMETest/data in ROOT format and in binary format.
- the data will be onlime merged with the CU data.
...