- CAL: this is done through the CAL tab in the Run Control main GUI. There's a button at the bottom of the tab for refreshing the BIAS DAC setting. The nominal value should be
.No Format 0x5800
- TKR: this is done through the TKRtab in the Run Control main GUI. There's a button for refreshing the level of the TKR bias voltage. The nominal value shuold be around
.No Format 100 V
Again: under normal conditions the bias voltages to the detectors should be on all the times and the shifters should not have to turn it on/off manually.
Selecting an application
The test application is choosen by pressing the Select Applicationbutton, which opens a file browser. Under normal circumstances the shifter should always select the application called
No Format |
---|
end2endBT.py
|
which, by the way, is the only test application into the default directory of the file browser. After the Open button is pressed, the file browser is closed and Run Control is ready to start.e2eBT
Starting a run